33
GB
TECHNICAL DATA
Supplier’s model identi
fi
er
S/SGA... - GSWH...
Model
50
80
100
120
Certi
fi
cate CE
51CT4894
Nominal capacity
I
50
75
100
80
Real capacity
I
54
75,7
99,3
75
Nominal pressure
bar
8
8
8
8
Nominal heat rating
kW
5
5
5
5
Useful rating
kW
4,3
4,3
4,3
4,3
Heating time for DHW t 45°C
min.
53
54
64
56
Heat loss at 60° Celsius
W
200 230 260
260
Hot water
fl
ow rate
supply at 30K
I/h
105
105
105
105
supply at 45K
l/h
79
79
79
79
Erp DHW
Declared Load pro
fi
le
M
M
M
M
Water heating e
ffi
ciency
η
wh
%
51
60
57
57
Water Heating e
ffi
ciency class
B
B
B
B
Daily electricity consumption Q
elec
kWh
--
--
--
--
Daily fuel consumption Q
fuel
kWh
13,27
11,0
11,63
11,63
Sound power level LWA L
WA
dB
58
58
58
58
Emissions of nitrogen oxides
[mg/kWh]
54
50
46
45
Annual electricity consumption AEC
kWh/annum
--
--
--
--
Annual fuel consumption AFC
GJ/annum
9,1
8,0
8,0
8,0
Mixed water at 40°C V40
l
93
114
170
180
Set-point temperature “out of the box”
°C
60
60
60
60
Thermostat temperature settings
5
5
5
5
Gas supply pressure
G20 Methane
mbar
20,0
20,0
20,0
20,0
G30 Butane LPG
mbar
29,0
29,0
29,0
29,0
G31 Propane LPG
mbar
37,0
37,0
37,0
37,0
gas consumption
G20 Methane
m
3
/h 0,529
0,529
0,529
0,529
G30 Butane LPG
Kg/h
0,394
0,394
0,394
0,394
G31 Propane LPG
Kg/h
0,388
0,388
0,388
0,388
Combustion gas values
Draught
mbar
0,015
0,015
0,015
0,015
Flue gas
fl
ow rate
g/sec
3,8
4,5
4,6
4,6
Flue gas temperature
°C
148
148
114
114
For the list of equivalent models refer to Annex A, an integral part of this booklet.
The products without the label and its board for sets of heaters and solar devices, provided for in Regulation 812/2013,
are not intended for use in such sets.