H
E
N
O
P
-- 50 --
bu09d12e2
6
OPERATION
General safety regulations for the handling of the equipment can be found on
page 44. Read through before you start using the equipment!
CAUTION!
When pulse welding make sure that the return cable (max. 8 m) and the connecting
cable (max. 8 m) between the power source and wire feed unit are not coiled up.
B
A
C
D
G
F
J
I F
G
J
K F M
L
G
TIG--Central connector
TIG--,OKC--connector
MMA, MIG/MAG
A
-- Power on/off
B
-- Cooling unit on/off (LUD 320W/450W)
C
-- Power on light
D
-- Thermal cut--out warning light, lights up in case of overheating
E
-- Welding terminal, + polarity
F
-- Welding terminal, -- polarity
G
-- Welding terminal, + polarity
H
-- Automatic fuse 42 V AC circuit
I
-- Central connector TIG torch, -- polarity HF
J
-- Water connection, TIG torch
K
-- OKC connector TIG torch, -- polarity HF
L
-- Connection for TIG torch trigger switch
M
-- Gas connection for TIG torch
N
-- Gas nipple (connection to gas bottle)
O
-- Termination resistance
P
-- Water connection, wire feed unit