Revised by R. Robinson
Issue AV1.13 8 June 2006
17
Zone 144 System Wide
Default value =
020
Range =
(000 ~ 255) *1 Sec.
This Zone sets the duration of ringing time before System Wide Call Forward transfers the call.
D.I.D:- If called ext is free,
applies to Sys Call Fwd time If ext is busy,
=0, Sys Call Fwd will not occur if the station is busy. Ie: 15 buttons must have reminder tone.
Related Zones.
,
.
Zones 145 to Zone 199 are Reserved
These Zones have no function.
Zone 200 PABX Out
Default value =
9
Range =
(0 ~ 9)
This Zone assigns the digit necessary to dial for accessing an outgoing line through a PABX.
Related Zones.
.
Zone 201 Operator
Default value =
0
Range = (0 ~ 9)
NOTE! This zone must not be the same digit as
This Zone allocates the digit to be dialed to access the console (operator).
Related Zones.
Zone 202 Dial-9 CO
Default value =
9
Range = (0 ~ 9)
NOTE! This zone must not be the same digit as
This Zone assigns the digit to be dialed when trying to access a free CO line.
Related Zones.
,
Zone 203
Toll Code
Default value =
0
Range =
(0 ~ 9)
This Zone assigns the digit to be dialed when trying to dial a Toll (STD) number.
Related Zones.
,
,
,
Zone 204
12/24 Clock
Default value =
0
Range =
(0 ~ 1)
This Zone allows the system time to be displayed as 12 Hour or 24 Hour formats.
Related Zones.
Zone 205
Ext Number LEN.
Default value =
2
Range =
(2 ~ 4)
This Zone allocates the number of digits (2, 3 or 4) in a station’s number.
Related Zones.