background image

AN1808-12S

 

4G

 Audio Intercom (E2.2) 

 10/16 

Enter System Menu 

1. Please call the number of the intercom.

2. The device will answer and sound one beep to enter system menu.

3. Enter the password of the mode you would like to enter.

3.1

 

Listener monitoring mode. 

*13*1212

#】

 

3.2

 

Access control mode 

*33*5678

#】

 

3.3

 

Program setting mode 

*12* 1234

#】

 

4. Password correct one is beep, password error is 3 beeps.

5. The device will hand up after 3 failed attempts.

Enter Listener Monitoring Mode 

1.

You will hear a “Do” tone to enter listener monitoring mode by pressing

*13*1212

#】

where 1212 is the monitoring password.

2.

Then you can hear the live sound of the device’s surrounding environment.

* Under this mode speaker is OFF. (35

: To turn on 

speaker)

* You can still control the relay output under listener monitoring mode but speaker must be

ON status.

Enter Access Control Mode 

1.

You will hear a “Do” tone to enter access control mode by pressing

*33*5678

#】

where

5678 is the access control password.

2.

The door will be opened after enter the correct password

*(To open the door by password, if the number is not stored in the access control section)

Enter Program setting Mode 

1.

You will hear a “Do” tone to enter into program setting mode by pressing

*12* 1234

#】

where 1234 is the setting password.

2.

You are now in the “program setting mode”

Note: At the end of each command there can be one of the two indications:

Successful: a long “beep” tone, failed: three short “beep” tone.

3.

To make changes on settings please refer to the command codes in page 12.

4.

To end program setting mode just hang up.

NOTE: 

*To be successful in programming, originate a call from a land line and enter the

digits slowly or using programming by text message.

Содержание AN1808-12S

Страница 1: ...AN1808 12S 4G Audio Intercom E2 2 1 16 AN1808 12S 4G LTE INTERCOM ACCESS CONTROL OPERATING MANUAL For your protection read these instructions completely Keep for future reference ...

Страница 2: ... Using the AN1808 12S 9 1 Setting your call out numbers 9 2 Setting your dial in numbers Guest list 9 3 App on iOS and Android 9 Enter System Menu 10 Programming by text message 11 Command Codes 12 Hardware reset if you forget password 15 How to change the name plate 14 Troubleshooting Q A 15 Specification 16 Setting your PINs 9 4 ...

Страница 3: ...nplug all the connections of product before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 3 Do not use this product near water 4 Do not use this product near an area where there is a potential of gas leaks or near any fumes that can be explosive 5 Do not place this equipment near or over a radiator or any other heat source 6 Do not overload the wall outlet o...

Страница 4: ...one keypad by pressing during the conversation and can also be activated by calling the SIM card in the unit from an authorized phone number guest The intercom will recognize an authorized phone guest number calling it and then not answer the call but will release the door or gate This call is free This intercom supports all Telstra Optus Vodafone CSFB networks Parts List Item Description Q ty 1 A...

Страница 5: ...AN1808 12S 4G Audio Intercom E2 2 5 16 Installation This intercom is suitable for both flush mounting and surface mounting Keypad Speake Microphone Call button ...

Страница 6: ...e bottom of the unit 1 4 Slide the SIM card holder towards the front of the unit 1 5 Lift up the holder 1 6 Before inserting the SIM card ensure that it is not PIN number locked If locked use a mobile phone to unlock it 1 7 Insert the SIM card Note orientation of notched corner 1 8 Replace holder and slide towards the rear of the unit to lock in place 1 9 Replace rear plastic cover ...

Страница 7: ... lock system Fig 2 2 1 According your door lock type see wiring diagram below 3 Connecting the Antenna Fig 3 3 1 Plug in the antenna cord to the connector on the rear of the unit 3 2 Place antenna away from electrical electronic systems computers microwave ovens etc ...

Страница 8: ...nect the 12 24v power source to the connector marked AC 4 2 The blue indicator of call button should be on and you will hear Du Du tone 4 3 Position the intercom where it will be installed 4 4 When the Du Du tone has ceased the device is ready Wiring Diagram ...

Страница 9: ...eive the reply as below 71 country code 72 relay call in number 1 72 relay call in number 2 OK 2 4 If a guest calls the number of the device it will trigger the relay to control the door latch 2 5 If the number is not on the guest list the device will answer and sound a beep Then the administrator can enter the programming mode by password 4 App on iOS and Android 3 1 Please search 4G intercom on ...

Страница 10: ...e relay output under listener monitoring mode but speaker must be ON status Enter Access Control Mode 1 You will hear a Do tone to enter access control mode by pressing 33 5678 where 5678 is the access control password 2 The door will be opened after enter the correct password To open the door by password if the number is not stored in the access control section Enter Program setting Mode 1 You wi...

Страница 11: ...immediately by a command 4 To program call button numbers DO NOT enter country code just the complete number as you would dial it Example Store a call button phone number Max 3 numbers and delete 2 3 phone numbers 058 57235 landline number 1 086 5682554 mobile number 2 086 2235644 mobile number 3 SMS format store a call button phone numbers 12 1234 1105857235 120865682554 130862235644 SMS format d...

Страница 12: ...crophone volume level 0 4 3 7 Relay 1 Trigger Time 51 relay1 time Relay 1 time 1 9999 sec 1 8 Relay 2 Trigger Time 50 relay 2 time Relay 2 time 1 9999 sec 1 9 Call Divert to next number time 52 call divert time Call divert time 10 99 sec 20 sec 10 Max Call Time 53 max call time Max call time 005 999 sec 060 sec 11 Max Monitoring time 55 duration time duration time 00 60 mins 00 no limit time 10 mi...

Страница 13: ...e 940 X X 1 1 code open code X 2 2 codes open code 1 25 Change open codes of relay 1 2 including trigger hold release for independent apartment 93 X ABCDEF X apartment number A B C D E F 0 9 and A trigger relay 1 B hold relay 1 C release relay 1 D trigger relay 2 E hold relay 2 F release relay 2 1 code 2 code 1 2 3 4 5 6 10 20 30 40 50 60 26 Send SMS message when Detect Pin is triggered 26 passwor...

Страница 14: ...Audio Intercom E2 2 14 16 30 Send SMS message when IN1 is triggered 30 password content Password setting password content up to 100 characters IN1 trigger 31 Reset 999 reset default None How to change the name plate ...

Страница 15: ...a has been mounted as high as possible not near large metal objects or wet green shrubs etc Q The unit calls the first number but there is not enough time to answer before it diverts to the next number A Increase the no answer time as per programming instructions Q The unit calls the first number but voicemail comes on before it can ring the second number A Decrease the no answer time as per progr...

Страница 16: ... A Check if you can hear the relay clicking at the gate when the 1 or 2 key is pressed during a call If it can be heard then the system is working check wiring between the relay and the lock or gate panel If the relays do not make a clicking sound then check this feature on a different mobile cell phone or landline If it works on a different phone check the settings on the phone in question under ...

Отзывы: