![Arista 7060 Series Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/arista/7060-series/7060-series_quick-start-manual_2970760030.webp)
Table 6: Switch Indicators LED States (Front)
LED Name
LED State
Device Status
Blinking Green
System is powering up.
Green
Normal operations. Due
to power supply and fan
redundancy, this LED will
remain green if a single fan or
power supply is missing or in a
failed state.
Blue
The locater function is active.
System Status LED
Amber
Two or more fans (any
combination of fan modules or
PSU fans) are disconnected
or malfunctioning. The switch
will automatically execute a
“graceful shutdown” shortly.
Green
All fan and power modules are
operating normally.
Amber
Single fan module is removed
or malfunctioning. It is
also amber when a PSU is
completely removed or has a
stuck fan rotor.
Fan Status LED
Red
Two or more fans (any
combination of fan modules or
PSU fans) are disconnected
or malfunctioning. The switch
will automatically execute a
“graceful shutdown” shortly.
Green
PSU is functioning and fully
operational. AC is present,
Aux output is ON, and Main
output is ON.
PSU [1:2] Status LED
Off
PSU has been removed or is
not operating properly due to
AC cord being unplugged, its
fan rotor being stuck, or an
internal fault.
26