Opto-Isolated Output (Port 3)
For some applications two opto-isolated outputs are available from the SCU5 controller. These outputs are
available on a 4-pin M12 female pin connector. A standard M12 4-pin A coded male connector or a pre-wired
M12 cable can be used for the connection. The pin functions for the connector are shown in the table below.
Pin
Color
Signal
1
Brown
VDD
2
White
OUT2
3
Blue
GND
4
Black
OUT1
The outputs can be used as NPN output by providing a VDD (5 - 24 VDC) and GND from a PLC and the signal
through the two outputs OUT1 and OUT2. Custom programing can be done to provide a GO/NO GO type of
output or a digital ON/OFF signal.
When the respective output
signal is enabled then that
signal would go low. And
normally the signal would be
high if wired as shown in the
schematic on the left.
Note that the outputs are
normally closed. If wiring a
relay, wire to the NC side of
the circuit so that the
appropriate output from the
relay is provided to the device.
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 13
Copyright © 2021 Roll-2-Roll Technologies LLC
+1-888-290-3215