MOUNT INSTRUCTIONS 

 

Wall mount must be capable of supporting a minimum 
weight of 50 lbs (22.7 kg). The wall mount bracket has 
holes on 16” centers to be secured to studs. If studs 
are not available, a plywood sheet mounted to the wall 
is recommended. Make sure holes are level.

Mount bracket with small slots in tabs pointing up.

SETUP 

Select a location for the unit which is near the water 
supply and electrical supply connections. If the water 
supply does not already have an isolation valve for 
servicing the Aries Lab System, install one ahead of 
the unit connection.

Install right-angle valve into the front of the unit outlet.

+VUV[PUZ[HSS[OLÄUHSJHWZ\SLÄS[LYPU[V[OLV\[SL[]HS]L
\U[PS[OLÄUHSZ[LWVMZ[HY[\W
<ZPUN[OL[\ILÄ[[PUNZWYV]PKLK^P[O[OL\UP[JVUULJ[

the unit inlet to the water supply.

+656;VWLU[OLZ\WWS`PZVSH[PVU]HS]L

 

H[[OPZ[PTL

INSTALLING THE CARTRIDGES

;OLYLHYL[OYLLJHY[YPKNLWVZP[PVUZ;OL^H[LYÅV^Z
MYVTSLM[[VYPNO[(U`WYL[YLH[TLU[ÄS[LYZT\Z[IL

installed in position #1 (furthest from the display) and a 

WVSPZOPUNÄS[LYT\Z[ILPUZ[HSSLKPUWVZP[PVUJSVZLZ[

to the display).

Locate the water purifying cartridges selected for your 

Z`Z[LT<U^YHW[OLÄS[LYZYLTV]L[OLZOPWWPUNWS\NZ
HUKHѝ_[OLSHILSZ

7SHJL[OLSHYNLVWLUPUNH[[OLIV[[VTVM[OLÄS[LYVU[V

the plunger. Push the cartridge down and tilt back 

\U[PS[OLÄS[LYPZHSPNULK^P[O[OL[VWWVZ[(SSV^[OL
ÄS[LY[VZSPKL\WV]LY[OL\WWLYÄ[[PUNHUKNLU[S`YV[H[L

left and right to insure a good seal with the top and 
bottom O-rings. 

9LWLH[HIV]LWYVJLK\YLMVYÄS[LYZHUK

Filters should always be installed in the 1,2,3 order 
and removed in reverse – 3,2,1.

05:;(3305.;/,<=)<3)67;065

WARNING – ELECTRICAL SHOCK HAZARD. 

4HRLZ\YLHSSWV^LYPZYLTV]LKMYVT[OLZ`Z[LT

Remove the top cover by removing the phillips head 
screws that attach it. Gently lift the top cover up and 
set it aside. The UV chamber will be visible in the top 
of the lab unit.

Unclasp the clamps that hold the stainless-steel body 
of the UV light. Gently lift the body up about 2 inches 
to allow clearance for bulb removal.

Unscrew the blue collar which is threaded into the 
stainless-steel body. Remove O-ring gasket and  
stainless-steel washer.

Tabs pointing up

I N S TA L L AT I O N   &   O P E R AT I O N   M A N U A L

  /   6

Содержание 931213

Страница 1: ...Copyright 2019 Aries FilterWorks All rights reserved ARIES High Purity Water System Installation Operation Manual...

Страница 2: ......

Страница 3: ...ears of trouble free operation Years of engineering and experience went into the design and manufacture of this instrument which will dispense water exceeding Type I water purity standards In order th...

Страница 4: ...ual or parts thereof may not be reproduced in any form without the express written permission of Aries Filterworks Inc Aries Filterworks is a registered trademark of ResinTech Inc Camden NJ USA For mo...

Страница 5: ...Check List Unpacking Guide 5 Main Check List 6 System Wall Mount Instructions 6 Setup 6 Installing the Cartridges 6 Installing the UV Bulb Option 7 Start up Procedure 8 Display and Key Pad 8 Resistivi...

Страница 6: ...pply Pressure should be regulated to meet the minimum and maximum ZWLJP JH PVUZ Z H LK MVY OL LX PWTLU Sanitization Make sure PPE is worn during any sanitization process The Aries system uses chlorine...

Страница 7: ...roximately 5 feet of span User manually dispenses water ARA DF Direct Feed Factory installed option Secondary Port on the side of the system Used to feed ancillary equipment such as HUHS aLYZ HUK ZJPL...

Страница 8: ...ATIONS PARAMETER REQUIREMENT Resistivity 4 JT 9LZPZ P P Microorganism 10 CFU mL T3 P O TPJYVU S YH S LY V SL TOC WWI P O VW PVU WWI PU LU Chlorides 1 ppb Sodium 1 ppb Endotoxin T3 P O TPJYVU S YH S LY...

Страница 9: ...VAC 60 Hz 1 0 amp 220 VAC 50 Hz 0 5 amp Dedicated GFCI protected outlet six feet within the system FEED WATER PRESSURE 30 80 psig regulated If gravity feed water is used HU L_ LYUHS KLSP LY W TW P O H...

Страница 10: ...ected to side system with IYHJRL TPJYVU S LY 7 PUJS KLK with ARA DG Direct Feed Port ARA DF Side port with CPC 3 8 Female panel mount 0UJS KLK JJLZZVYPLZ PUHS PS LY HZ V LYLK P O ZWLJP J TVKLS 6 SL HU...

Страница 11: ...he display and a WVSPZOPUN S LY T Z IL PUZ HSSLK PU WVZP PVU JSVZLZ to the display Locate the water purifying cartridges selected for your Z Z LT U YHW OL S LYZ YLTV L OL ZOPWWPUN WS NZ HUK H _ OL SHI...

Страница 12: ...l circuit Open outlet valve and place a container underneath Slowly turn on the water supply to the unit and correct any leaks at the supply connections Turn unit on at the power switch and allow wate...

Страница 13: ...OPERATION AND PROGRAMMING TO CHECK WATER TEMPERATURE Press and Hold TEMP The water temperature is displayed while the button is pressed The monitor returns to normal operation when released The displa...

Страница 14: ...HNL 0 W YP LZ H LY OH TLL Z VY L_JLLKZ OL ZWLJP JH PVUZ YLJVTTLUKLK by CLSI ASTM for Type I Reagent Grade Water when it is operated and maintained according to these instructions The ultraviolet lamp...

Страница 15: ...HYL YLWSHJLK SANITIZATION Use Sanitization Kit HPA 010 YU V Z Z LT HUK KPZJVUULJ WV LY WS N Open dispense valve Remove cartridges 9LTV L TPJYVU UHS S LY Insert sanitization cartridges in the following...

Страница 16: ...pair Kit for Upper Outlet and Plunger 3 sets HPA 013 3V LY P PUN 9LWHPY 2P 0UJS KLZ ZL Z VM WS UNLY J W ZWYPUNZ V YPUNZ HUK PUNZ HPA 014 WWLY 9LWHPY 2P 0UJS KLZ ZL Z VM WWLY PUNZ PF 00 6402 TPJYVU JHW...

Страница 17: ...WHY PJSLZ and plugged 5V V VU YT OH OL Z WWS H LY PZ YULK VU Have unit serviced by an authorized dealer or return to factory 9LWSHJL OL S LY JHY YPKNL HWZ SL S LY PZ IV UK P O HPY 6WLU bleed valve Dis...

Страница 18: ...h Inc assumes no other responsibility or liability This warranty does not cover any product which has been subject to misuse neglect accident or used in violation of operating instructions nor does it...

Страница 19: ...ARIES WATER PURIFICATION MAINTENANCE LOG Serial Number Date Installed Asset or ID Location DATE MAINTENANCE PERFORMED BY COMMENTS INSTALLATION OPERATION MANUAL 14...

Страница 20: ...DATE MAINTENANCE PERFORMED BY COMMENTS...

Страница 21: ...DATE MAINTENANCE PERFORMED BY COMMENTS...

Страница 22: ...DATE MAINTENANCE PERFORMED BY COMMENTS...

Страница 23: ......

Страница 24: ...LKLYHS YLL HTKLU 51 CORPORATE HEADQUARTERS CALL 856 626 1550 OR VISIT US ONLINE ARIESFILTERWORKS COM M 0530201701 Rev 8...

Отзывы: