Before installation:

 

1. 

You must ensure that water inlet, electricity and drain pipe are ready and suitable for installation of the product. We refer to the 

technical specifications in this manual. Use a splash proof socket to connect the product with the power supply. The drain hose has 

a diameter of 40mm. The water inlet hoses have ½”-connections. 

2. 

The water connection hoses are resistant to high pressure. Before you connect the hoses, flush the supply pipes first so all possible 

dirt particles from the pipes are flushed out. 

3. 

Use taps on the jack in the wall. Any repairs or maintenance on the product can be done without having to close the main valve of 

the water. 

4. 

Ensure that there is enough space to connect the various parts. 

5. 

After extracting the product parts, check that all parts are complete and that there is no visible errors, missing parts, or damages. 

How to operate the faucet:

 

 

 

Installation instructions:

 

1. 

Be sure that the product is installed correctly. We recommend to install the product by an expert. The product must be installed 

on the floor with all feet before use. Levelling the product is an important topic. 

2. 

Electrical installation and testing shall be performed by approved electrician. 

3. 

Power to the product must meet the requirements of the product described in this manual. 

4. 

Protective devices for leakage, overload of power or incorrect voltage must be installed and working. 

5. 

Do not cut or extend electrical wires / power cord during installation of the product. 

6. 

Do not disassemble the control panel or computer controller as this is not designed for disassembly. Defects, damages or 

           

shock caused by such removal can’t be charged to the supplier or its distributors. 

 
 

 

A: Change over valve:

 

Water jets 

Hand shower 

Waterfall 

OFF 

 
 

 

Air regulator:

 

 
 

 

 
 

 

B: Temperature adjustment:

 

H for hot water                    

L for cold water 

 

7. 

For electrical installations the local standards must be followed. 

8. 

The motor must be grounded with wire not less than 1mm. 

9. 

Earthed appliances must be permanently connected to fixed wiring. 

10. 

Parts incorporating electrical components, except remote control devices, must be located or fixed so that they cannot fall into 

the bath; 

11. 

The appliance should be supplied through a residual current device (RCD) having a rated residual operating current not 

exceeding 30 mA. 

12. 

Parts are installed in the correct zone and that equipotential bonding is carried out. 

13. 

Electrical installation shall be in accordance with National Regulatory requirements. 

14. 

Connect the supply for hot & cold water in the right way up (red=hot, blue=cold). 

15. 

Organic chemicals such as acetone, ammonia or gasoline can dissolve or damage the product. Do not use these chemicals for 

cleaning or installation. 

16. 

Do not support or stack anything on the product. Take special care when moving the product so that no pressure will be 

charged unnecessary. 

17. 

Maintain good ventilation in the room product is installed in. 

18. 

Be sure that the hot and cold water hoses will not touch the floor when the product is pushed in the correct place. This will 

minimize the chance of getting rust on the hoses. 

 

 

 

  

 

 
 
 

 

Maintenance:

 

When to clean the whirlpool use a soft sponge and a detergent without ammonia and acetone to prevent the surfaces in the whirlpool 

gets math.

 

The drain can be caused by hair, soap scum and such clogging. Clean the drain regularly.

 

The chrome parts are carefully polished. Do not use polishes with abrasives or other chemicals that may affect the chrome parts of your 

whirlpool. Try not to remove stains with hard objects, such as knives. To clean, use a damp cloth.

 

Bad maintenance / cleaning can cause damage to the faucets and jets.

 

Clean the whirlpool with a whirlpool cleaner monthly. Follow the instructions on the bottle. Lime, soap, grease, oil, hair, bacteria and dead 

skin care can contaminate your whirlpool system. If not cleaned regularly, you can get black flakes in the bath. If this happens, you 

should clean the whirlpool system with a whirlpool cleaner so often in succession to clean up the black flakes and have it completely 

disappeared.

 

 

Warning

: the use of cleaning materials other than those recommended by the manufacturer can result in  

damage to the bath and/or the whirlpool apparatus 

Warning

: To be adjusted (repaired) only by installers who can demonstrate to the appropriate authorities awareness and competence in the 

application of National Regulatory requirements for safety, i.e. electrical and water supply/disposal 

 
 

 

  

 

Page 3 / 9 

Page 8 / 9 

 

Содержание Whirlpool BT series

Страница 1: ...User manual Whirlpool Serial number ...

Страница 2: ...before or during use of the product may lead to unconsciousness and possible drowning or increased risk of fatal output of heat stroke 4 Persons suffering from obesity or with a medical history that includes the use of medication for heart problems low or high blood pressure problems with blood circulation or diabetes should consult a doctor before using theproduct 5 Persons using medication shoul...

Страница 3: ...ge must be installed and working 5 Do not cut or extend electrical wires power cord during installation of the product 6 Do not disassemble the control panel or computer controller as this is not designed for disassembly Defects damages or shock caused by such removal can t be charged to the supplier or its distributors 7 For electrical installations the local standards must be followed 8 The moto...

Страница 4: ...m on and operate for a minimum period of 10 min Without draining down switch the whirlpool system off and after a minimum period of 10 min check all pipework joints and connections for possible leaks After any necessary adjustment to ensure the integrity of the installation or the replacement of any faulty elements repeat the procedure 5 You must ensure that the product works as expected Test all ...

Страница 5: ... pump and air pump both work but with a different start time both pumps will automatically turn off after 20 minutes To stop the water pump press the water pump button for two seconds On the display you can see off To be able to adjust the water force the water pump has to be working Press the SET button until you see F on the display Press the parameter setting keys to select a force level betwee...

Страница 6: ...dio is activated you can adjust the volume using the parameter setting buttons from 0 19 3db is default To search for a new radio channel press the set button then use the parameter setting buttons to select channel If you press the parameter setting buttons for 2 seconds the system will automatically search for a channel Press the memory button to save the selected channel On the display CH chann...

Страница 7: ...e air pump button the air pump will start and blow warm air through the bottom jets The air pump will automatically shut down after 20 minutes If the water level changes from above to below the sensor the air pump will stop automatically The icon of the air pump will start to flash In order to activate the air pump again press the air pump button If the water pump and air pump both work at the sam...

Страница 8: ... Bad maintenance cleaning can cause damage to the faucets andjets Clean the whirlpool with a whirlpool cleaner monthly Follow the instructions on the bottle Lime soap grease oil hair bacteria and dead skin care can contaminate your whirlpool system If not cleaned regularly you can get black flakes in the bath If this happens you should clean the whirlpool system with a whirlpool cleaner so often i...

Страница 9: ...mp AC220V 240 60HZ 1500W Air pump AC220V 240 60HZ 200W Lighting AC12V 7W Speaker 8Ω 10W Test standaard EN 12764 2004 A1 2008 EN 60335 2 60 Low Voltage Directive 73 23 EEC EN 1111 1 The instructions for appliances connected to the water mains shall state the maximum inlet water pressure is 0 5mPa 5 bars the minimum inlet water pressure is 0 1mPa if this is necessary for the correct operation of the...

Отзывы: