19 Operation on an ISDN Access
214
ARGUS 152
BRI
termination
You can add terminating resistors to a BRI access.
Setting:
In NT mode:
In TE mode:
Leased line:
Terminating resistor switched in
No terminating resistor is switched in
No terminating resistor is switched in
Any change to this setting will not be saved permanently; it will only
apply to the current measurement.
Call
parameters
Four different parameters can be set for (ISDN) calls generated on
both the network-side (ARGUS in NT mode) and on the user-side
(ARGUS in TE mode):
1. Type of number (TON) for the CGN (=CGPN) or CDN (=CDPN)
element of a SETUP signal
Network-side:
Net CGN TON
Net CDN TON
User-side:
User CGN TON
User CDN TON
Default setting:
unknown
2. Numbering Plan for the CGN (=CGPN) or CDN (=CDPN) element
of a SETUP signal:
Network-side:
Net CGN NP
Net CDN NP
User-side:
User CGN NP
User CDN NP
3. CGN/CDN Subaddress
CGN/CDN Sudaddress Type: User specific and NSAP
Default setting:
User specific
4. UUI (User User Info)
*For more information, see Prefix on page 215.
Services
Up to three user-specified services (user spec. 1 to user spec. 3) can
be entered and saved. For each "user spec. service“, you must enter
the info-elements BC, HLC and LLC in hexadecimal (switch with the
left softkey). To do so, use the keypad and the A . . F softkey (e.g. to
enter a "C", press the softkey three times; for an "F", press it six
times).