Configuration
This section discusses calibration, printing configuration and
resetting the printer to factory defaults.
Performing Calibration
1. Press and hold the feed button while turning on
the power, until the printing motor is activated.
2. Calibration is performed while the printer automatically feeds
the label stock for a certain length.
Important!
You must always carry out calibration when
changing media. Failure to do so will result in improper detection
by the label sensor.
Printing a Configuration Report
1. Press and hold the feed button while turning on the power, until
the printing motor is activated.
2. After feeding 12-inch blank media, the printing motor suspends
for one second and then prints out a configuration profile. The
profile includes firmware version, ROM checksum, RS-232,
thermal transfer/direct thermal settings, hardware configuration,
and font types.
3. At PPLB emulation, the printer enters character dump mode.
To exit from dump mode, press the feed button again. (If you
accidentally print the label without exiting from dump mode in
advance, you need to turn on the printer again to print
normally.)
34
Resetting to Factory Default Settings
1. Turn on the printer and wait for 5 or more seconds.
2. Press the "Feed" button for 10 seconds, and the "Ready"
indicator and "Power" indicator will go off in order.
3. After two LEDs relight, release the feed button.
4. The printer will feed a label length, and resets to the
factory default settings.
Note: All settings are stored in non-volatile E2PROM and are
retained even after turning off the printer.