A Guide to Wall Mounting & Fixings

Important note: 

If plastic wall plugs (rawl plugs) 
are supplied with your product, 
e.g.:

- these are only suitable for use in 
masonry walls.

If you are in any doubt about the 
correct wall plugs for your wall, 
seek professional advice.

Failure of the product due to 
using the incorrect fixings is the 
responsibility of the installer.

       

 Important:

 when drilling into walls always check 

that there are no hidden wires or pipes etc.

Make sure that the screws and wall plugs being used are suitable for 
supporting your unit. Consult a qualified tradesperson if you  
are unsure.
Hints:

1:  General rule: 

 always use a larger screw and wall plug if you are 

not sure.

2:  Ensure you use the recommended drill bit to match the wall plug and 

hole size.

3:  Ensure you drill the hole horizontally; do not force the drill or enlarge 

the hole.

4:  Take extra care when drilling high walls, ceilings and ceramic tiles. 

Ensure wall plugs are inserted beyond the thickness of the ceramic 
tiles to avoid the tiles splitting or cracking.

5:  Ensure wall plugs are well fitted and are a tight fit in the  

drilled hole.

Types of walls 

No.1 “General Purpose” wall plug

Generally aerated blocks should not 
be used to support heavy loads, use 
a specialist fitting in this case. For 
light loads, general purpose  
wall plugs can be used.

No.3 “Cavity Fixing” wall plug

For use with plasterboard partitions 
or hollow wooden doors.

No.5 “Hammer Fixing” wall plug

For use with walls stuck with 
plasterboard. The hammer fixing 
allows it to be fixed to the wall  
rather than the plasterboard.  
Always check the fixing is secure  
to the retaining wall.

No.2 “ Plasterboard”  

wall plug

For use when attaching light loads 
onto plasterboard partitions.

No.4 “ Cavity Fixing – Heavy Duty” 

wall plug

For use when fitting or supporting 
heavy loads such as shelving, wall 
cabinets and coat racks.

No.6 “ Shield Anchor” wall plug – 

heavy loads

For use with heavier loads such as 
TV and HiFi speakers and satellite 
dishes etc.

              

Care & 
Maintenance

Safety: 

always check the fitting and 

location to ensure your safety in and 
around the home.

Fitting:

 from time to time check the 

fitting to ensure the wall plugs or 
screws do not become loose.

You can use one of the following types of wall plug if your walls are made 
of brick, breeze block, concrete, stone or wood.

Содержание Under Basin Unit 833/2763

Страница 1: ...ight 60 cm Important Please read these instructions fully before starting assembly If you need help or have damaged or missing parts call the Customer Helpline 0845 640 0800 Assembly Instructions please keep for future reference Issue 2 09 09 10 833 2763 ...

Страница 2: ...could cause damage Assemble the item as close to its final position in the same room as possible Assemble on a soft level surface to avoid damaging the unit or your floor Parts of the assembly will be easier with 2 people We do not recommend the use of power drill drivers for inserting screws as this could damage the unit Only use hand screwdrivers Dispose of all packaging carefully and responsibl...

Страница 3: ...2 Left side x 1 58 5 h cm x 28 5 d cm 3 Right side x 1 58 5 h cm x 28 5 d cm 4 Base x 1 40 w cm x 28 d cm 5 Bottom rail x 1 6 9 h cm x 40 w cm 6 Left door x 1 49 2 h cm x 19 7 w cm 7 Right door x 1 49 2 h cm x 19 7 w cm 8 Back panel x 2 52 h cm x 10 w cm 9 Internal shelf x 1 42 w cm x 25 6 d cm 1 ...

Страница 4: ...w x 2 Magnetic catch x1 E F G H Back panel screw x 10 Wooden dowel x 5 Hinge x 4 Knob x 2 I J K L 16mm Screw x 2 Catch plate x 2 10mm Screw x 2 Shelf bracket x 4 Tools required Phillips screwdriver medium large Ruler Use this ruler to help correctly identify the screws 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 110 115 120 125 130 135 140 145 150 155 160 165 170 105 Assembly Ins...

Страница 5: ...uctions O P M N 833 2763 833 2811 Step 1 In order to prevent accidental toppling it is recommended to secure the unit to a wall using the supplied safety strap Connect safety strap O to rear of the unit as shown using 1 x 20mm screw P note this screw replaces the back panel screw E detailed in the main instructions Step 2 Secure safety strap to wall using 30mm screw M and rawl plug N as shown Note...

Страница 6: ...n Step 3 Screw 2 x 35mm male camlock A into the holes at the bottom of the left side 2 and right side 3 as shown Insert 2 x female camlock B into the holes at the top of the left side 2 and right side 3 as shown Step 4 Insert 5 x wooden dowel F into the bottom rail 5 as shown B 4 A B 3 A B 2 F 5 ...

Страница 7: ...ase 2 with a screwdriver a Note you should feel a click when the camlocks are secured Step 7 Connect right side 3 to other end of assembly completed in Step 5 as shown Tighten female camlocks in underside of base 2 with a screwdriver see Step 6 a Note you should feel a click when the camlocks are secured Note it may be helpful to have assistance from another person with this stage 5 4 a 2 3 2 ...

Страница 8: ...of doors 6 and 7 as shown Note it may be helpful to have assistance from another person with the next stage Locate door hinges in place in base as shown then connect the top panel 1 ensuring that top hinges of doors slot into place b and tighten female camlocks on inside of left and right side with a screwdriver see Step 6 a Note you should feel a click when the camlocks are secured b H H 6 7 I J ...

Страница 9: ... the Customer Helpline 0845 640 0800 Assembly Instructions Step 9 Connect back panels 8 using 10 x back panel screw E as shown Step 10 Insert 4 x shelf bracket L inside the unit at the desired height as shown and set internal shelf 9 in place Assembly complete 8 8 E L 9 ...

Страница 10: ...gs are well fitted and are a tight fit in the drilled hole Types of walls No 1 General Purpose wall plug Generally aerated blocks should not be used to support heavy loads use a specialist fitting in this case For light loads general purpose wall plugs can be used No 3 Cavity Fixing wall plug For use with plasterboard partitions or hollow wooden doors No 5 Hammer Fixing wall plug For use with wall...