6-2. Place and Space for Installation
●
Choose a place as cool as possible. The place should
be well ventilated, and the intake air should not be
hotter than the outside temperature.
(max. 45°C)
●
Avoid the vicinity of heat sources, exhaust fans, etc.
(Fig. 6-4)
●
Avoid direct sunlight, provide awning if necessary.
●
Required space around the outdoor unit for free air
flow and servicing is given in Figs. 6-5a,
and 6-5c.
The avoid the effects of humidity and ground moisture,
the unit should be placed on concrete blocks or slab at
least 10 cm high above ground level.
(Figs. 6-6a )
The unit must be level and be anchored securely to its
base with anchor bolts or the like. An unsteady
foundation will cause abnormal noise and vibration.