![Argoclima 387007114 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/argoclima/387007114/387007114_technical-data-and-service-manual_2967804023.webp)
OUTDOOR UNIT:
AER522SC
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,39
0,55
12,1
13,0
Power input
Kw
0,075
0,124
2,551
2,750
Full load conditions
Running Amps.
A
0,39
0,55
14,1
15,0
Power input
Kw
0,075
0,124
3,101
3,300
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
NOTE: Data referred to indoor unit
AWR522CL
model.
For other indoor unit models could be the same difference.
Outdoor unit
230V 1-Phase 50 Hz