6. ELECTRICAL DATA
6-1 Electrical characteristics
OUTDOOR UNIT:
AER518SC
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,37
0,40
9,23
10,0
Power input
Kw
0,070
0,086
2,044
2,200
Full load conditions
Running Amps.
A
0,37
0,40
11,23
12,0
Power input
Kw
0,070
0,086
2,494
2,650
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
NOTE: Data referred to indoor unit
AWR518CL
model.
For other indoor unit models there could be the same differences.
Outdoor unit
230V 1-Phase 50 Hz
21