1 - GENERAL PRECAUTION
• Check that the voltage and frequency of the power supply match those required by the system.
• Check the possibility to have the power line to the indoor unit
(ELECTRIC CABLE LENGTH 3 m).
• Install a double - pole switch, protected by 10 A fuses of the delayed type, upstream the electricity wall socket.
• Make sure that the electrical installation is suitable to supply continuosly current necessary for the air conditioner in
addition to that already used by other electric appliances (white goods, lighting). See the max electric imput indica-
ted on the name plate positioned on the air conditioner.
•
Before connecting the air conditioner to a power socket, make sure that the socket is provided with an earth
connection in compliance with local codes.
2 - INSTALLATION SITE SELECTION
INDOOR UNIT
AVOID:
• Positioning the indoor unit into rooms where it could be sprinkled with water (i.e. laundries).
• Installation in areas where leakage of flammable gas or large amount of mist may be expected humidity location.
• Direct sunlight or near by heat source that may affect performance of the unit.
• Installing the unit behind curtains or furniture that obstruct air circulation.
DO:
• Choose a position which allows proper ventilation in the room.
• Verify respect of the minimum recommended maintenance space.
OUTDOOR UNIT
AVOID:
• Direct sunlight or area where hot air from exhaust fans investing the unit.
DO:
• Choose a place as cool as possible and well ventilated.
• Synthetic oil HAB - Alkylbenzene type ex. EXXON ZERICE S, about 30 gr.
• PVC pipe to insulate hole in the wall, external diameter 50 mm. of minimum length as for thickness wall.
• Phillips head screw driver • Tape measure • Level • Hammer drill • Hole saw or key hole saw ø 50
• 19 mm wrench • 21 mm wrench • 24 mm wrench • Hammer • Hacksaw • Core bits 10 mm diameter drill bit.
TOOLS REQUIRED FOR INSTALLATION (NOT SUPPLIED)
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
3 - ACCESSORIES AND TOOLS REQUIRED FOR INSTALLATION
THE EXTENSION KITS ARE SUPPLIED PRECHARGED
NARROW TUBE
LARGE TUBE
OUTSIDE DIA.
OUTSIDE DIA.
6,35 mm
7,93 mm
Before the installation, verify that they are fit for the unit.
CONNECTION EXTENSION KITS -
LENGHT OF 2 OR 4 m
ACCESSORY SUPPLIED ON REQUEST
FIGURE PARTS NR°
EXTENSION KIT
FOR CONNEC-
1
TION TUBE
CONNECTIONS
1
PLASTIC BOX
RAWL PLUG
3
TAPPING SCREW
3
ø 3,5 x 45
CLAMP
2
OUTDOOR UNIT SUPPORT
BRACKET KIT
RAWL PLUG
3
S X 10
SCREW 7x65
3
WASHER
3
OUTDOOR UNIT
SUPPORT AND
1+1
GUIDE
SCREW 4,2x13
2
ACCESSORY SUPPLIED ON REQUEST
ACCESSORIES
SUPPLIED WITH THE UNIT
FIGURE PARTS NR°
REMOTE
UNIT CONTROL
1
BATTERIES FOR
REMOTE CONTROL 2
PLASTIC PLUG
(MALE AND
2 + 2
FEMALE)
FELT PADS
4
SUPPORTS FOR
REMOTE UNIT
2
CONTROL
35*+
9+:
:[XHU
+IU
4OMNZ
,ORZKX
:OSKX
2OMNZ
S
1
M
W
T
T
F
S
AUTO
WEEK
SET
2
3
A