![Argo ULISSE ECO Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/argo/ulisse-eco/ulisse-eco_installation-manual_2967557011.webp)
EN
11
The remote control can be addressed to use up to 4 different units installed in the same room.
You can get unified control by using a single remote control for all units or each remote control can be addressed to
its own unit, in order to control separately temperature, timer and all other functions.
12 - MATCH BETWEEN REMOTE CONTROLLER AND THE UNIT
PCB SETTING
•
Disconnect the unit power supply and wait at least 60 seconds, mak-
ing sure that all the lamps go off.
•
Remove the rear panel and the cover of the electrical box to access
the pcb.
•
Set JP2 and JP3 as shown in the table.
•
Close the cover of the electrical box and the rear panel.
•
Reconnect the unit power supply.
REMOTE CONTROLLER SETTING
•
Press the button for a few seconds.
•
Press the arrow until you visualize 06.
•
Press the button again for a few seconds: the number 0 (factory
setting) at the bottom starts flashing.
•
Press the arrow to set 1, 2 or 3.
•
Confirm with the button .
•
Press to exit the menu.
35*+
9+:
35*+
9+:
35*+
9+:
0
FACTORY STATE
JP2=CLOSE JP3=CLOSE
1
JP2=OPEN JP3=CLOSE
2
JP2=CLOSE JP3=OPEN
3
JP2=OPEN JP3=APERTO
REMOTE CONTROL UNIT
PCB
UNIT