CLEANING AND MAINTENANCE 

 

MAINTENANCE OF THE HUMIDIFIER’S EXTERIOR SURFACE 

 

 

Warning 

 Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric 
shock and malfunction.  
 

 

Warning 

Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.  
 
Use a damp and soft cloth to clean the exterior surface of the dehumidifier. 
Do not use solvents, petrol, xylene, talcum powder or brushes to clean the unit: these may damage 
the surface or colour of the casing. 

 

 

CLEANING THE WATER TANK 

 
We advise removing the tank once every few weeks to prevent mould and bacteria forming on it.  Fill the tank with clean 
water a small amount of detergent; swill the water around in it, then it out and rinse it thoroughly.  
 
 

CLEANING THE AIR FILTER 

 

 

The filter is designed to remove dust or dirt from the air.  

If the filter is clogged by dust, electricity consumption will be higher than 
normal.  
 
Cleaning instructions: 

1.  Remove the tank. 
2.  Remove the filter by pulling the flap and pulling down the 

filter until complete extraction. Clean the filter with a vacuum 
cleaner or wash it with clean water at no more than 40°C.                                                                             
DO NOT USE ALCOHOL, BENZENE OR OTHER 
AGGRESSIVE PRODUCTS TO CLEAN THE FILTER.     Leave 
the filter to dry naturally, then reposition it in the relevant 
slot. 

3.  Reinsert the filter pushing it upwards until you hear a sound. 
4.  Reposition the tank.  

 
Do not use the dehumidifier without the filter as dust may affect the 
efficiency of the evaporator, resulting in higher energy consumption. 

 

 

 
 
 
 
 
 

Содержание LILIUM EVO 11

Страница 1: ...INSTRUCTIONS Read the instructions carefully before operating or servicing the dehumidifier Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference EN ...

Страница 2: ...rgy efficiency The units therefore need less filling Warning Do not try to accelerate the defrosting process or to clean the appliance in different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Argoclima Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance has to be stored in a room that do...

Страница 3: ...and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision This product is not a toy Children of less than 3 years should be kept away unless continuously supervised Make sure the plug is i...

Страница 4: ...m the wall or other obstacles so that the heat can dissipate correctly Close all open windows to maximise dehumidification efficiency Do not insert objects or sharp instruments into the air outlet grille Do not cover the air intake and outlet grilles in any way WARNING In the event of an anomaly switch the appliance off and unplug it immediately Do not dismantle repair or modify this product freel...

Страница 5: ... the appliance while it is operating doing so can cause leaks and malfunction DESCRIPTION OF PARTS The following space must be maintained to ensure the operating efficiency of the dehumidifier FRONT VIEW REAR VIEW Air outlet ...

Страница 6: ...tes must pass before the dehumidifier starts up again this delay prevents the compressor being damaged If on the other hand the set humidity percentage is higher than the level currently found in the room the dehumidifier will not start If you follow the start up instructions but the dehumidifier does not start stops for no reason make sure the plug and power cord are in good working order After d...

Страница 7: ... off the appliance and remove the plug before connecting the hose Remove the drain hole cap and connect a PVC hose supplied to the drain hole Connect the hose to water drain The height of the drainage hose must not exceed that of the hole do not block the drainage hose exit Occasionally check that the adapter and drainage hose are tightly connected and not damaged or blocked ...

Страница 8: ...rresponding led indicator lights on 4 FAN BUTTON Press this button to set the fan speed high and low speed the corresponding led lights on NOTE This button is valid only when DEUMIDIFY and FAN mode are set 5 TIMER ON OFF BUTTON Press this button to set the timer from 1 to 24 hours If the timer is set to 0 and you press TIMER button or there is no operation in 5 seconds the dehumidifier will automa...

Страница 9: ...the corresponding LED will turn on DEHUMIDIFY mode the compressor is workable and the fan speed is adjustable The initial humidity is 55 low speed Humidity range is 30 80 adjustable AUTOMATIC mode the compressor is workable and the fan speed is un adjustable The initial humidity is 55 and can t be set Fan speed is automatic If the humidity is higher than 70 the compressor is working and the fan sp...

Страница 10: ...er a small amount of detergent swill the water around in it then it out and rinse it thoroughly CLEANING THE AIR FILTER The filter is designed to remove dust or dirt from the air If the filter is clogged by dust electricity consumption will be higher than normal Cleaning instructions 1 Remove the tank 2 Remove the filter by pulling the flap and pulling down the filter until complete extraction Cle...

Страница 11: ...ank even when using the hose for continuous condensation drainage Check the drainage connections The drainage hose is not connected properly Connect the hose correctly Remove the drainage hose and replace it The ON OFF LED does not turn on when the power is connected There is no power or the plug is not inserted correctly Check the electrical power supply Make sure that the electric circuit and pl...

Страница 12: ... WITH EUROPEAN DIRECTIVE 2012 19 EU This appliance may not be scrapped with domestic waste at the end of its life cycle We call your attention to the crucial role played by the consumer in the re use recycling and other forms of recovery of such waste The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer no charge is levied for this service when you pu...

Отзывы: