Argo EVAN PLUS Скачать руководство пользователя страница 9

 

V 01/22

 

28

HOW TO USE THE APPLIANCE 

 

This appliance can be used for cooling, heating, dehumidifying and ventilating.  
When switching between modes, the fan continues to rotate but the compressor stops: the compressor will start after 3 
minutes. This delay protects the compressor from potential damage. 

 
 

 
 

 

Cooling, Fan, Heating                               

 

Dehumidifying  

 
THE DISCHARGE TUBE MUST ALWAYS BE CONNECTED to the appliance: the only exception is when the 
appliance is used solely for dehumidification, in which case it is advisable to let the appliance discharge directly 
into the environment for maximum efficiency (consult the "Dehumidification Mode" paragraph). 

Regularly clean the air filters beneath the easily removable rear grille to keep the air conditioner working efficiently. 
 

OPERATING MODES 

1. COOLING MODE (COOL) 

 

The “Cool” LED on the control panel will turn on. 

 

The temperature can be adjusted to between 16 °C and 31 °C. 

 

In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the 
temperature 

 

setting and retains this setting when it is switched on again. 

 

In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set. 

 

For more silent operation, run the fan at low speed. 

 

2. HEATING MODE (HEAT) 

 

The “Heat” LED on the control panel will turn on. 

 

The temperature can be adjusted to between 16 °C and 31 °C. 

 

In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the 
temperature 

 

setting and retains this setting when it is switched on again. 

 

In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set. 

 

For more silent operation, run the fan at low speed. 

 

3. DEHUMIDIFICATION MODE (DRY) 

 

Press the MODE button to select the dehumidification mode. 

 

The temperature is controlled by the electronic board and cannot be adjusted. 

 

In this mode, each time the ON/OFF button is pressed the unit switches off, the appliance saves the settings 
and 

 

retains them when it is switched on again. 

 

The fan speed is set to low and cannot be adjusted. 

 

NOTE 

The air conditioner does not cool the room when operating as a dehumidifier. 
When the appliance is used as a dehumidifier, the flexible pipe must not be connected. 

For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into 
the environment. 

The dehumidification mode is recommended during autumn and winter. 

If used during summer, it is best to leave the flexible pipe attached so that the hot air is discharged towards 
the outside rather than into the room. 

During dehumidification, continuous drainage should be implemented (see the next chapter, “HOW TO ELIMINATE 
CONDENSATE”). 
 

 
 

Содержание EVAN PLUS

Страница 1: ...NS Read the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or...

Страница 2: ...different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Service Centre Any repairs carried out by unqualified personnel may be danger...

Страница 3: ...be made by children without supervision Ensure that the electricity system is able to deliver the operating current required by the air conditioner in addition to that normally absorbed by other appl...

Страница 4: ...he remote control to OFF and remove the plug from the socket Pull on the plug only Do not pull the cord Do not use the appliance if the cord or plug are damaged If the power supply cord is damaged it...

Страница 5: ...on a flat and stable surface so as to avoid water leaks The air conditioner is fitted with a system for protecting the compressor from overload This means that the compressor only starts 3 minutes af...

Страница 6: ...held liable if safety and accident prevention rules are not observed DESCRIPTION OF THE APPLIANCE FRONT VIEW REAR VIEW 1 CONTROL PANEL AND FUNCTION BUTTONS WITHOUT REMOTE CONTROL 2 FLAP AIR INTAKE AN...

Страница 7: ...he following space must be maintained to ensure the operating efficiency of the portable air conditioner The unit must be placed vertically for 2 hours before the first power on APPLIANCE START UP Ope...

Страница 8: ...af towards it USE WITH WINDOW KIT 1 To make the hole in the glass it is advisable to take the porthole kit accessory to the glazier 2 Insert the window unit B into the window 3 Insert the round fittin...

Страница 9: ...E HEAT The Heat LED on the control panel will turn on The temperature can be adjusted to between 16 C and 31 C In this mode each time the ON OFF button is pressed the unit switches off the appliance s...

Страница 10: ...d blocking the operation of the device Cooling and Heating When the unit operates in the cooling and heating mode ensure that the rubber cap closing the drainage opening on the back of the appliance i...

Страница 11: ...rical quantity is lacking and the battery must be replaced 12 Battery waste must be disposed of properly Note The image is a general remote control it contains almost all the function keys They may be...

Страница 12: ...ime C Sleep on off D Speed setting E Display timer and temperature F Swing on off G Timer set H Signal transmission I Heating mode L Battery level 1 ON OFF BUTTON When turned on the unit emits an audi...

Страница 13: ...g Unit Press TIMER Press Timer again to select a number of hours from 1 to 24 Press the TIMER button to confirm Resetting the timer If a TIMER has been set press TIMER to display the delay Press TIMER...

Страница 14: ...ds talcum powder and brushes they may damage the surface or colour of the casing Remove any stains using warm water with a little neutral detergent Do not pour water onto the air conditioner to clean...

Страница 15: ...0 21 0 00063 Tons CO2 equiv Do not release R290 into the atmosphere INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT pursuant to art 26 Legislative Decree 14 03 14 no 49 IMPLEMENTATION OF EUROPEAN...

Страница 16: ...refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry powder or CO2 fire extinguisher adjacent to the charging area No ignitio...

Страница 17: ...ents are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall beat the correct rating Replace components only with parts specified by the...

Страница 18: ...menced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for han...

Страница 19: ...ered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially n...

Отзывы: