Argo dados 40 Скачать руководство пользователя страница 6

 

6

V 07/13 

3. HEATING MODE 

   

 

Press FUNCT to select Heating until the relevant icon appears. 

 

By default, the temperature is set to 25ºC. 

 

The temperature can be adjusted between 15° and 25°C. 

 

In this way, each time the Power button is pressed, the unit switches off, the appliance saves the temperature set 
and when switched back on again, it will retain this setting. 

 

In this way, fan speed can be adjusted; the Timer and ECO function can be set. 

 

TO USE THE AIR-CONDITIONER IN HEATING MODE, ROTATE THE PRODUCT 180º AROUND ITSELF AND 
CONNECT THE CONNECTOR AND THE FLEXIBLE HOSE AS USUAL; THEN SELECT THE HEATING FUNCTION 
ON THE REMOTE CONTROL OR, IF YOU DO NOT HAVE A REMOTE CONTROL, ON THE CONTROL PANEL. 

 
 

4. FAN MODE

 

 

 

 

Press FUNCT  to select Fan until the relevant icon appears.  

 

When the unit operates in this mode, the display will show FF and the icon 

lights up.

 

 

This enables the adjustment of fan speed. 

 

The temperature cannot be regulated. 

 
 
 

HOW TO ELIMINATE CONDENSATE

 

 
This equipment automatically vaporises the condensation in Cooling and Heating mode. 
Ensure that when the unit operates as Cooling or Heating, the rubber cap that closes the discharge hole at the back is 
correctly positioned. 
 
When the air-conditioner operates on 

Cooling and Heating

, there is no need to arrange for continuous drainage of 

condensate; only in specific weather conditions where air humidity levels are very high may water deposit within the unit. 
When the internal tank is full, the blue LED flashes to warn that it is full and blocks the appliance function. 

 
 
To empty the container, switch the air-conditioner off and unplug. Remove the 
rear drainage hole cap and connect a little tube through which to drain the 
condensation; place the other end on top of a normal drain. 
Ensure that the tube is not twisted or bent. The tube must slope downwards. 
Close the drain again with the cap and resume use of the air-conditioner. 
 
 

ATTENTION! 

When using the air-conditioner in 

Dehumidification mode, we recommend 

always 

ensuring 

continuous drainage

, in order to guarantee maximum 

dehumidification efficiency. 
 
 
 
 

 
 
 
 
 
 
 

 

Содержание dados 40

Страница 1: ...ead the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference EN ...

Страница 2: ... while it is operating first turn the appliance off check and remove any condensation that may have formed To turn the appliance off set the remote control to OFF and remove the plug from the socket Only pull on the plug Do not pull the cord Do not use the appliance if the cord or plug are damaged If the power supply cord is damaged it must be replaced by the manufacturer dealer or a similarly qua...

Страница 3: ...By Flash ON OFF 1 6 sec ON 1 6 sec OFF Full Tank 1 CONTROL PANEL FUNCTION BUTTONS FOR OPERATION WITHOUT REMOTE CONTROL 2 3 TERMINAL CONNECTOR OF THE AIR EXPULSION TUBE 4 AIR EXPULSION TUBE 5 REMOTE CONTROL RECEIVER 6 COOL AIR OUTLET COMPLETE WITH AIR LOUVERS 7 8 INLET GRILLES 9 CONDENSATE DRAIN HOLE 10 HOT AIR OUTLET 11 POWER CORD 12 CONCEALED WHEELS 13 BLUE OPERATING LED 14 TOUCH SCREEN REMOTE CO...

Страница 4: ... the air expulsion mouth and the flexible hose positioned between the window leafs Window slider kit Flexible exhaust hose Position the product vertically on a firm flat surface as close to a window as possible keeping a minimum distance of 50 cm from walls or other nearby obstacles Connect the connection 1 to the flexible hose 2 extend the hose as necessary to reach the outside and connect it to ...

Страница 5: ...nditioner will operate in Cooling mode with the temperature set to 25ºC by default The temperature can be adjusted between 17 and 30 C In this way each time the Power button is pressed the unit switches off the appliance saves the temperature set and when switched back on again it will retain this setting In this way fan speed can be adjusted the Timer ECO function can be set 2 DEHUMIDIFICATION MO...

Страница 6: ...O ELIMINATE CONDENSATE This equipment automatically vaporises the condensation in Cooling and Heating mode Ensure that when the unit operates as Cooling or Heating the rubber cap that closes the discharge hole at the back is correctly positioned When the air conditioner operates on Cooling and Heating there is no need to arrange for continuous drainage of condensate only in specific weather condit...

Страница 7: ...eiver Transmitter head INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2006 66 EC Please replace batteries when flat at the end of their useful life batteries must not be disposed of with unsorted waste It must be must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service Separate waste disposal of batteries p...

Страница 8: ... every half hour for the next 2 hours it then remains stable for the rest of the time 2 Each time the electricity power supply is disconnected eco mode is cancelled To restore simply press the ECO button once Each time the appliance is switched off eco mode is cancelled To restore simply press the ECO button once 7 TIMER BUTTON TIMER ON TIMER OFF 1 Timer on auto on When the appliance is on stand b...

Страница 9: ... position resting on the lower side now remove the filters pulling them delicately upwards Use a vacuum cleaner to remove dust If this should not suffice wash the filters with warm water and a neutral detergent if necessary Rinse with cold water and leave to air dry before replacing Once the two filters have been replaced close the grilles once again and return to using the air conditioner 2 Clean...

Страница 10: ...ification F GAS REGULATION EC no 842 2006 Do not release R410A into the atmosphere R410A is a fluorinated greenhouse gas covered by the Kyoto protocol with a global warming potential GWP of 1975 INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2002 96 EC When this appliance reaches the end of its useful life it must not be disposed of with household waste I...

Страница 11: ...d Consumer Act 2010 This guarantee excludes damage by neglect shipping or accident and any damage due to incorrect installation use or purpose other than those intended or failure to observe the instructions Atlantic Australasia reserves the right to reject any warranty claim used in conditions other than domestic purposes or deemed to be false All retail warranty claims must be pre approved by At...

Отзывы: