HOW TO USE THE APPLIANCE

 

 
This appliance can be used to Cool, Dehumidify, Fan and Heat. In changing from one mode to another, the fan continues 
operating but the compressor stops; the compressor starts up again 3 and a half minutes later.

 This delay in start-up 

protects the compressor from any damages.   

 

IMPORTANT! 

To operate in 

Cooling, Dehumidifying and Fan 

mode, the air-conditioner must be positioned with the air outlet fitted with 

deflectors positioned to the front. 
 
To operate in 

Heating 

mode, the appliance must be rotated 180º so as to have the air outlet without deflectors to the front; 

using the remote control or Power switch on the control panel, select the 

Heating mode 

(see the chapter entitled 

OPERATION). 

 

THE DISCHARGE TUBE MUST BE CONNECTED to the appliance AT ALL TIMES: the only exception is when the 
appliance is used for Dehumidification only, in which case it is recommended that the appliance discharges 
directly into the environment to obtain maximum efficiency (see the paragraph entitled "Dehumidification Mode"). 

Clean the air filters under the easily removable side panels regularly to keep the air-conditioner working efficiently. 

 

OPERATING MODES 

 

1. COOLING MODE 

 

  The first time it is turned on, the air-conditioner will operate in Cooling mode with the temperature set to 25ºC by 

default. 

  The temperature can be adjusted between 17° and 30°C. 

  In this way, each time the Power button is pressed, the unit switches off, the appliance saves the temperature set 

and when switched back on again, it will retain this setting. 

  In this way, fan speed can be adjusted, the Timer, ECO function can be set. 

 

2. DEHUMIDIFICATION MODE 

  

 

Press FUNCT to select Dehumidification until the relevant icon appears. 

 

The temperature is controlled by the electronic card and cannot be regulated. 

 

In this way, each time the Power button is pressed, the unit switches off, the appliance saves the settings and when 
switched back on again, it will retain them. 

 

Fan speed is fixed to low and cannot be adjusted. 

 

NOTE 

The air-conditioner does not cool the environment when operating as a dehumidifier.  
When the appliance is used as a dehumidifier, the flexible hose must not be connected.  

For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into 
the environment.   

Dehumidification mode is recommended in autumn and winter.  

If used in the summer, it is best to leave the flexible hose attached, in order to send the hot air outside rather 
than releasing it into the environment. 

During dehumidification, it is best to ensure continuous drainage (see paragraph entitled "HOW TO ELIMINATE 
CONDENSATION"). 
 

 

Cooling,  Heating and Fan

 

 

Dehumidifying 

 

Содержание dados 40

Страница 1: ...ead the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference EN ...

Страница 2: ... while it is operating first turn the appliance off check and remove any condensation that may have formed To turn the appliance off set the remote control to OFF and remove the plug from the socket Only pull on the plug Do not pull the cord Do not use the appliance if the cord or plug are damaged If the power supply cord is damaged it must be replaced by the manufacturer dealer or a similarly qua...

Страница 3: ...By Flash ON OFF 1 6 sec ON 1 6 sec OFF Full Tank 1 CONTROL PANEL FUNCTION BUTTONS FOR OPERATION WITHOUT REMOTE CONTROL 2 3 TERMINAL CONNECTOR OF THE AIR EXPULSION TUBE 4 AIR EXPULSION TUBE 5 REMOTE CONTROL RECEIVER 6 COOL AIR OUTLET COMPLETE WITH AIR LOUVERS 7 8 INLET GRILLES 9 CONDENSATE DRAIN HOLE 10 HOT AIR OUTLET 11 POWER CORD 12 CONCEALED WHEELS 13 BLUE OPERATING LED 14 TOUCH SCREEN REMOTE CO...

Страница 4: ... the air expulsion mouth and the flexible hose positioned between the window leafs Window slider kit Flexible exhaust hose Position the product vertically on a firm flat surface as close to a window as possible keeping a minimum distance of 50 cm from walls or other nearby obstacles Connect the connection 1 to the flexible hose 2 extend the hose as necessary to reach the outside and connect it to ...

Страница 5: ...nditioner will operate in Cooling mode with the temperature set to 25ºC by default The temperature can be adjusted between 17 and 30 C In this way each time the Power button is pressed the unit switches off the appliance saves the temperature set and when switched back on again it will retain this setting In this way fan speed can be adjusted the Timer ECO function can be set 2 DEHUMIDIFICATION MO...

Страница 6: ...O ELIMINATE CONDENSATE This equipment automatically vaporises the condensation in Cooling and Heating mode Ensure that when the unit operates as Cooling or Heating the rubber cap that closes the discharge hole at the back is correctly positioned When the air conditioner operates on Cooling and Heating there is no need to arrange for continuous drainage of condensate only in specific weather condit...

Страница 7: ...eiver Transmitter head INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2006 66 EC Please replace batteries when flat at the end of their useful life batteries must not be disposed of with unsorted waste It must be must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service Separate waste disposal of batteries p...

Страница 8: ... every half hour for the next 2 hours it then remains stable for the rest of the time 2 Each time the electricity power supply is disconnected eco mode is cancelled To restore simply press the ECO button once Each time the appliance is switched off eco mode is cancelled To restore simply press the ECO button once 7 TIMER BUTTON TIMER ON TIMER OFF 1 Timer on auto on When the appliance is on stand b...

Страница 9: ... position resting on the lower side now remove the filters pulling them delicately upwards Use a vacuum cleaner to remove dust If this should not suffice wash the filters with warm water and a neutral detergent if necessary Rinse with cold water and leave to air dry before replacing Once the two filters have been replaced close the grilles once again and return to using the air conditioner 2 Clean...

Страница 10: ...ification F GAS REGULATION EC no 842 2006 Do not release R410A into the atmosphere R410A is a fluorinated greenhouse gas covered by the Kyoto protocol with a global warming potential GWP of 1975 INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2002 96 EC When this appliance reaches the end of its useful life it must not be disposed of with household waste I...

Страница 11: ...d Consumer Act 2010 This guarantee excludes damage by neglect shipping or accident and any damage due to incorrect installation use or purpose other than those intended or failure to observe the instructions Atlantic Australasia reserves the right to reject any warranty claim used in conditions other than domestic purposes or deemed to be false All retail warranty claims must be pre approved by At...

Отзывы: