![Argo AW720HL Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/argo/aw720hl/aw720hl_service-manual_2967487021.webp)
5-4 Dry Mode Operation
Dry operation remove moisture from indoor air running, in cooling mode, at a low level without reducing the
ambient temperature. This is done cycling ON and OFF indoor and outdoor units according to below.
ROOM
DRY LEVEL
TEMP
≥
SPT+2°C
LEVEL 0
Operation according to COOLING mode
CM on
< SPT+2°C
LEVEL 1
FMO on
≥
SPT-1°C
FMI switches between L and LL (30 seconds)
RV off
CM switches 9 minutes off and 3 minutes on
< SPT-1°C
LEVEL 2
FMO switches 9 minutes off and 3 minutes ON
≥
15°C
FMI switches off and L during CM operation
RV off
CM off
< 15°C
DRY OFF ZONE
FMO off
FMI off
RV off
SPT = Set Point Temperature
5-5 Fan Mode Operation
With this mode, the indoor fan is turned on while CM, FMO and RV stay off all the time. The user can select
between 3 speeds: HIGH, MEDIUM and LOW.
5-6 Auto Fan speed
With this option selected, the indoor fan speed changes automatically according to the difference between
the detected air temperature (RAT sensor) and the set point (SPT):
COOLING MODE
2
≤
(RAT – SPT):
HIGH speed
1
≤
(RAT – SPT)
<
2:
MEDIUM speed
(RAT – SPT)
<
1:
LOW speed
HEATING MODE
2
≤
(SPT - RAT):
HIGH speed
(SPT - RAT)
<
2:
MEDIUM speed
NOTE
SPT = Set Point Temperature
21
Содержание AW720HL
Страница 11: ...2 DIMENSIONAL DATA AW720HL AW726HL AW735HL AW726CL AW735CL AW720 726 12 7 1 2 AW735 11...
Страница 12: ...AW726HLF AW735HLF AW726CLF AW735CLF...
Страница 16: ...4 ELECTRICAL DATA 4 1 Electric Wiring Diagrams HEAT PUMP MODELS COOLING MODELS 16...
Страница 17: ...4 2 Wiring System Diagram HEAT PUMP MODELS COOLING MODELS 17...
Страница 32: ...6 5 SOME PARTS OF THE AIR CONDITIONER DO NOT OPERATE 32...
Страница 33: ...6 6 AIR CONDITIONER OPERATES BUT ABNORMALITIES ARE OBSERVED 33...
Страница 34: ...34...
Страница 35: ...6 7 POOR COOLING OR HEATING 35...
Страница 36: ...6 8 EXCESSIVE COOLING OR HEATING 6 9 A SENSOR IS DEFECTIVE 36...
Страница 39: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com...