Argo AT062310B Скачать руководство пользователя страница 10

14

SOURCE POWER, 240V/60HZ/1PH 3-WIRE, BY

 OTHERS

(SOURCE DU COURANT

, 240V/60HZ/1PH 3-FILS, OU AUTRES)

NEUTRAL

 BLOCK

(BLOC NEUTRE)

WHT/BLK (BLANC/NOIR)

WHT

 (BLANC)

N

WHT

 (BLANC)

WHT/BLK (BLANC/NOIR)

WHT

 (BLANC)

WHT

 (BLANC)

ELEMENT

 #4 RELA

YS

(RELAIS DE ĽÉLÉMENT

 No4)

WHT/BLK (BLANC/NOIR)

ELEMENT

 #4

(ÉLÉMENT

 No4)

OFF

(FERMÉ)

N

C2

120V

AC

CIRC

L

C1

H4

L2

L

N

120V

AC

INPUT

(ENTRÉE)

TRANSFORMER

(TRANSFORMA

TEUR)

H3

L2

L1

H4

CIRC

ON

(OUVER

T)

CONTROL

(COMMANDE)

BLK (NOIR)

ARGO "A

T" ELECTRIC BOILER

SCHEMA

TIC WIRING DIAGRAM

4 ELEMENT

 BOILER,

WITH BREAKERS

L2

L1

ARGO LOAD CENTER

(CENTRE DE CHARGE ARGO)

THERMOST

AT

, BY

 OTHERS

(THERMOST

AT

, OU AUTRES)

RED (ROUGE)

T-

T

HL

ELEMENT

 #2 RELA

YS

(RELAIS DE ĽÉLÉMENT

 No2)

ELEMENT

 #3 RELA

YS

(RELAIS DE ĽÉLÉMENT

 No3)

WHT/BLK (BLANC/NOIR)

ELEMENT

 #3

(ÉLÉMENT

 No3)

ELEMENT

 #2

(ÉLÉMENT

 No2)

H2

HEA

TING ELEMENTS  ENERGIZED

(ACTIV

ATION DES 

ÉLÉMENTS DE 

CHAUFF

AGE)

H3

L1

RED (ROUGE)

H2

L1

FAUL

T

(DÉF

AILLANCE)

4

2

L2

3

1

LW

C

FLOW FLOW

LW

C

ELEMENT

 #1 RELA

YS

(RELAIS DE ĽÉLÉMENT

 No1)

WHT

 (BLANC)

ELEMENT

 #1

(ÉLÉMENT

 No1)

DIFFERENTIAL

(DIFFÉRENTIEL)

H1

L1

SETPOINT

(RÉGLAGE)

H1

L2

TT TT HL

RT

D

WHT

 (NOIR)

WHT/BLK (BLANC/NOIR)

WHT

 (BLANC)

WHT/BLK (BLANC/NOIR)

WHT/BLK (BLANC/NOIR)

WHT

 (BLANC)

WHT/BLK (BLANC/NOIR)

WHT

 (BLANC)

RED (ROUGE)

WIRE LEGEND / (LÉGENDE DES FILS)

-  DR

Y CONT

ACT

 WIRING (POSE DES C

Â

BLES DE CONT

ACT

 SEC)

-  120 VOL

T WIRING (POSE DES C

Â

BLES 120 VOL

T)

-  240 VOL

T WIRING (POSE DES C

Â

BLES 240 VOL

T)

-  120 VOL

T FIELD WIRING (POSE DES C

Â

BLES 120 VOL

T SUR EN CHANTIER)

-  240 VOL

T FIELD WIRING (POSE DES C

Â

BLES 240 VOL

T EN CHANTIER)

(DIAGRAMME SCHÉMA

TIQUE DU CÂBLAGE 

D'UNE CHAUDIÈRE À 4 ÉLÉMENTS)

-  DR

Y CONT

ACT

 FIELD WIRING (POSE DES C

Â

BLES DE CONT

ACT

 SEC

EN CHANTIER)

EQUIPMENT

 GROUNDING LUG

(TENON DE PRISE Á LA

 TERRE DE Ľ APP

AREIL)

OPTIONAL

 FLOW SWITCH, BY

 OTHERS

(INTERRUPTEUR DE DÉBIT

 - F

ACUL

TA

TIF

, OU AUTRES)

SOURCE POWER, 120V/60HZ/1PH , BY

 OTHERS

(SOURCE DU COURANT

, 120V/60HZ/1PH, OU AUTRES)

OPTIONAL

 LWCO, BY

 OTHERS

(ISPOSITIF D'ARRET

 EN CAS F

AIBLE NIVEAU D'EAU - 

FACUL

TA

TIF - OU AUTRES)

HIGH LIMIT

 SAFETY

 SWITCH, AUT

O RESET

(INTERRUPTEUR DE SÉCURITÉ DE LIMITE SUPÉRIEURE, 

REMISE EN MARCHE AUT

OMA

TIQUE)

HIGH LIMIT

 SAFETY

 SWITCH, AUT

O RESET

(INTERRUPTEUR DE SÉCURITÉ DE LIMITE 

SUPÉRIEURE, REMISE EN MARCHE AUT

OMA

TIQUE)

FACT

OR

Y INST

ALLED JUMPERS

(CAL

VALIERS INST

ALLÉES Á ĽUSINE)

RTD W

ATER TEMPERA

TURE SENSOR

(CAPTEUR DE LA

 TEMPÉRA

TURE DE ĽEAU R

TD)

CIRCULA

TOR PUMP

, BY

 OTHERS

(POMPE DE ĽACCELER

TEUR, OU AUTRES)

CIRCULA

TOR RELA

Y

(RELAIS DU

ĽACCELER

TEUR)

ARGO ELECTRONIC BOILER CONTROL

(COMMANDE ÉLECTRONIQUE DE LA

 CHAUDIÈRE ARGO)

SAFETY

 SWITCHES

(INTERRUPTEURS DE SÉCURITÉ)

Wiring diAgrAms

figurE 8B

Содержание AT062310B

Страница 1: ...ting brackets for easy wall mounting Use of lag screws or anchor bolts through holes provided or on 3 4 plywood panel On uneven walls suggested mounting surface be provided such as two 2 x 4 s Surface...

Страница 2: ...p supply may be located in this area below Circulator pump should be installed on supply side pumping away 6 Install gate valves at locations shown in Figures 2 3 so any boiler servicing requiring rem...

Страница 3: ...7 primary secondary piping for Multiple zoning with ZONE VALVES primary secondary piping for Multiple zoning with circulators PRIMary secondary piping figure 2 figure 3...

Страница 4: ...e ends before inserting into terminal block Tighten terminal screws Do not use pump rated greater than 5 amps Thermostat Connect thermostat or zone valve end switch to terminals TT and TT Figure 4 Do...

Страница 5: ...re sizes specified conform to Canadian Electrical Code Canada or National Electric Code USA and include derating for ampacity and temperature Use copper wire only Check state and local requirements Re...

Страница 6: ...or will continue to be energized for 3 minutes to purge boiler After 3 minutes control will de energize circulator Circ LED turns off If during start up or during operation safety end switch opens its...

Страница 7: ...TACT SEC 120 VOLT WIRING POSE DES C BLES 120 VOLT 240 VOLT WIRING POSE DES C BLES 240 VOLT 120 VOLT FIELD WIRING POSE DES C BLES 120 VOLT SUR EN CHANTIER 240 VOLT FIELD WIRING POSE DES C BLES 240 VOLT...

Страница 8: ...HERS SOURCE DU COURANT 120V 60HZ 1PH OU AUTRES OPTIONAL FLOW SWITCH BY OTHERS INTERRUPTEUR DE D BIT FACULTATIF OU AUTRES THERMOSTAT BY OTHERS THERMOSTAT OU AUTRES ELEMENT 1 L MENT No1 ELEMENT 1 RELAYS...

Страница 9: ...T BLK BLANC NOIR WHT BLANC FUSE BLOCK BLOC DE FUSIBLE BLK NOIR L2 L1 POWER BLOCK BLOC DE PUISSANCE 240 VOLT FIELD WIRING POSE DES C BLES 240 VOLT EN CHANTIER EN CHANTIER 120 VOLT WIRING POSE DES C BLE...

Страница 10: ...NOIR WHT BLANC RED ROUGE WIRE LEGEND L GENDE DES FILS DRY CONTACT WIRING POSE DES C BLES DE CONTACT SEC 120 VOLT WIRING POSE DES C BLES 120 VOLT 240 VOLT WIRING POSE DES C BLES 240 VOLT 120 VOLT FIELD...

Страница 11: ...as the pressure remains less than 25 PSIG Hydronic block is now ready to be put into service Verify hydronic block circuit breaker or switch at service 1 entrance and depending on option hydronic blo...

Страница 12: ...cluded with this manual Turn off hydronic unit circuit breaker at service en 1 trance and or disconnect switch Close gate valves near inlet and outlet of hydronic 2 block noisy boiler heating element...

Отзывы: