LENGTH, SIZE WIRES AND DELAYED FUSE
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
●
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with
foamed polyethylene (min. thickness 8mm).
●
PVC pipe for condensate drain pipe (ø int.18mm) in length suitable to let the condensate flow into the outside drainage.
●
Anti-freeze oil for flare connections (about 30g.).
●
Electric wire: use insulated copper wires of size and length as shown at paragraph “SYSTEM WIRING DIAGRAMS”.
Supply power wire A:
Multipolar electric wire. Size and length of the suggested electric wire are showed on table “electrical data”. The wire
must be Mod. H07RN-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between
the fixing point and the terminals allows the straining of the conductors L, N before that of the grounding.
Connecting wire B (SHIELDED):
Bipolar electric shielded wire; size and length of the suggested electric wire are showed on table “electrical data”.
The wires have not to be lighter than Mod. H05VVC4V5-K (according to CEI 20-20 CENELEC HD21).
Connecting wire C (with ground conductor):
Multipolar electric wire; size and length of the suggested electric wire are showed on table “electrical data”. The
wires have not to be lighter than Mod. H07RN-F (according to CEI 20-19 CENELEC HD22).
NARROW TUBE
LARGE TUBE
INDOOR UNIT SIZE
OUTER DIAMETER
MIN. THICKNESS
OUTER DIAMETER
MIN. THICKNESS
A
6,35 mm
0,8 mm
9,52 mm
0,8 mm
B - C - D
6,35 mm
0,8 mm
12,7 mm
0,8 mm
B - C - D (HK)
9,52 mm
0,8 mm
15,88 mm
1 mm
D (ASI)
9,52 mm
0,8 mm
15,88 mm
1 mm
EMIX - EMIX TANK
12,7 mm
0,8 mm
12,7 mm
0,8 mm
쐽
Cooling Maximum conditions
Outdoor temperature
:
43°C D.B.
Room temperature :
32°C D.B. / 23°C W.B.
쐽
Cooling Minimum conditions
Outdoor temperature
: –15°C D.B.
Room temperature :
10°C D.B. / 6°C W.B.
쐽
Heating Maximum conditions
Outdoor temperature
:
24°C D.B. / 18°C W.B.
Room temperature :
27°C D.B.
쐽
Heating Minimum conditions
Outdoor temperature
:
–15°C D.B.
Room temperature :
5°C D.B.
OPERATING LIMITS
MODEL
mm
2
MONO SPLIT
AEI1G140
DUAL SPLIT
12,5 A
TRIAL SPLIT
QUADRI SPLIT
PENTA SPLIT
20
30
30
20
30
30
20
30
30
20
50
50
20
30
30
L ("A") m
L ("B") m
L ("C") m
4
0,75
1,5
EG
Содержание AEI1G140 3PH
Страница 12: ...GIG 4 2 INDOOR UNITS 3 INDOOR UNITS POWER SUPPLY AC 380 415V 3PHASE 50Hz POWER SUPPLY AC 380 415V 3PHASE 50Hz ...
Страница 20: ...4 FG 2 INDOOR UNITS 3 INDOOR UNITS POWER SUPPLY AC 380 415V 3PHASE 50Hz POWER SUPPLY AC 380 415V 3PHASE 50Hz ...
Страница 28: ...DG 4 2 INDOOR UNITS 3 INDOOR UNITS POWER SUPPLY AC 380 415V 3PHASE 50Hz POWER SUPPLY AC 380 415V 3PHASE 50Hz ...
Страница 36: ...EG 4 2 INDOOR UNITS 3 INDOOR UNITS POWER SUPPLY AC 380 415V 3PHASE 50Hz POWER SUPPLY AC 380 415V 3PHASE 50Hz ...
Страница 44: ...PG 4 2 INDOOR UNITS 3 INDOOR UNITS POWER SUPPLY AC 380 415V 3PHASE 50Hz POWER SUPPLY AC 380 415V 3PHASE 50Hz ...
Страница 52: ...GGR 4 2 INDOOR UNITS 3 INDOOR UNITS POWER SUPPLY AC 380 415V 3PHASE 50Hz POWER SUPPLY AC 380 415V 3PHASE 50Hz ...
Страница 62: ...14 9 ASID ASIC 10 EMIX PORT SEE EMIX UNIT OR EMIX TANK INSTALLATION MANUAL ASIC 11 ...
Страница 63: ...15 12 ASID ASIC 13 EMIX PORT SEE EMIX UNIT OR EMIX TANK INSTALLATION MANUAL 14 ...
Страница 65: ...17 ...
Страница 85: ...37 ...
Страница 86: ......
Страница 87: ......