Argo-Hytos SD2EX-B2 Скачать руководство пользователя страница 20

Subject to change_SD2EX-B2(B3;B4)_14064_1en_05/2022

Page 20

www.argo-hytos.com

A sealing ring in the recess behind the thread ensures the valve is sealed in the block and prevents working fluid from leaking out of the block.Sealing 
rings on the steel valve housing separate the individual channels in the port from each other. If the ring is not fitted or is damaged, unwanted 
interconnection of the channels and unreliable control function of the valve will occur. In this case, the valve must be removed from the port and the 
sealing rings replaced with new ones.

 › Ensure that no explosive atmosphere is present during the repair (see also 7.5). 
 › Switch off the pressure source (pump) of the hydraulic circuit (see also 7.5).
 › Relieve the hydraulic circuit including the accumulators by connecting it to the tank (see also 7.5)
 › Ensure that the hydraulic circuit is de-pressurized (see also 7.5).
 › Switch off the electrical supply to the valve solenoids  (viz také 7.5).
 › Ensure that the surface of the valve and solenoid coils is cooled to a low enough temperature to prevent skin burns (see also 7.5)
 › Clean the surface and around valve.
 › Loosen the coil nut with a wrench (a = 36) and unscrew it.
 › Remove the sealing ring and spool from the valve control system.
 › Loosen the valve with a wrench (a = 27) and carefully unscrew it.
 › Allow the remaining working fluid from the valve to drain into the prepared smaller container. Dry the valve surface with a cleaning cloth.
 › Using a suitable tool, e.g. a small screwdriver, remove any sealing rings. Work carefully, do not damage the valve housing and threads.  

 

  Check the valve for damage and cleanliness.

 › Use a replacement seal kit. Thread the sealing rings into the recesses one by one in the correct place. Do not confuse the seals! Lubricate the new  

  seals with grease or working fluid.

 › Check the chamber in the block for damage and cleanliness.
 › When installing the new replacement valve into the block, follow section 7.2 Product installation.
 › After reassembling the solenoid to the valve control system, check that the solenoid cable in the grommet and the ground wire are properly  

 

  secured to ensure that they have not come loose during manipulation of the solenoid.

 › After the repair, verify that the new seals are tight and the valve is functioning properly.

7.6.2 Replacing the sealing rings on the valve housing

Remove residual working fluid from the dismantled defective valveand package it to prevent mechanical damage and contamination of the area 
outside the package during transport. Send the packaged valve with a description of the manifestation of the defect to the manufacturer. A new 
valve is warranted by the manufacturer for 1 year. However, a claim may not be accepted by the manufacturer if the valve is mechanically damaged, 
the seal material is damaged by aggressive liquid, or the valve has been shown to have been used improperly and not in accordance with these 
instruction of use of use.

A defective control solenoid coil may only be replaced with the manufacturer‘s original replacement coil with identical parameters.

 › Switch off the pressure source (pump) of the hydraulic circuit (see also 7.5).
 › Switch off the pressure source (pump) of the hydraulic circuit (see also 7.5).
 › Relieve the hydraulic circuit including the accumulators by connecting it to the tank (see also 7.5).
 › Make sure that the hydraulic circuit is de-pressurized (see also 7.5).
 › Switch off the electrical supply to the valve solenoids (see also 7.5)..
 › Ensure that the surface of the valve and solenoid coils is cooled to a low enough temperature to prevent skin burns (see also 7.5).
 › Clean the surface and surroundings of the valve.
 › Disconnect the coil surface ground wire.
 › Disconnect the coil cable from the power supply. 
 › Loosen the coil fastening nut by turning it anti-clockwise using the wrench a = 36. Remove the nut.
 › Remove the sealing ring (1) 21.89x2.62, the coil and the second sealing ring 22x1.5 from the control system tube. 
 › Check the surface condition of the control system for damage, e.g. corrosion. 
 › Connect the power supply cable to the new coil according to point 7.2.1, unless a coil with an already connected cable has been supplied by the                

  manufacturer. We recommend using a new cable to connect the new coil. Replace the sealing rings with new ones. They are supplied in a set with  

  the coil and a new fastening nut.

 › Těsnicí kroužky cívky nahraďte novými. Jsou dodávány v sadě s cívkou a novou upínací maticí.
 › Fit a new 22x1.5 sealing ring, a new coil with attached cable, a new 21.89 x 2.62 sealing ring and screw on a new clamping nut on the control    

  system tube. Tighten the nut with a wrench to a torque of 5 + 1 Nm.

 › Connect the ground wire to the new coil. 
 › Po ukončení výměny cívky zkontrolujte správnou funkci ventilu.

7.6.3 Coil replacement

Hydraulic block

Control system

Coil

Mounting nut

Sealing ring (1)
21.89x2.62

Sealing ring (2)
22x1.5

Содержание SD2EX-B2

Страница 1: ...E DESIGNED FOR USE IN EXPLOSIVE ATMOSPHERES SD2EX B2 SD2EX B3 SD2EX B4 EN The following is the authorised translation of original operating instruction SD2EX B2 B3 B4 no 14054_1cz_03 2022 issued by th...

Страница 2: ...Subject to change_SD2EX B2 B3 B4 _14064_1en_05 2022 Page 2 www argo hytos com Prohl en o shod...

Страница 3: ...Subject to change_SD2EX B2 B3 B4 _14064_1en_05 2022 Page 3 www argo hytos com...

Страница 4: ...Subject to change_SD2EX B2 B3 B4 _14064_1en_05 2022 Page 4 www argo hytos com...

Страница 5: ...ace protection against corrosion 9 4 4 Basic technical parameters 10 4 5 Working fluid 10 4 6 Valve characteristics 10 4 7 Legislation and standards 11 5 Product modifications 12 6 Target group of use...

Страница 6: ...ctice the unit used is bar 1bar 0 1MPa DANGER Signal word combined with a warning sign used to signify that a dangerous situation which could result in death or serious injury is imminent WARNING Sign...

Страница 7: ...C T100 C T85 C Db Ex tb IIIC T135 C T100 C T85 C Db Area of aapplication 2 2 Cable grommet The cable grommet is a separately certified component with ATEX and IECEx certification I M2 Ex eb I Mb II 2...

Страница 8: ...aximum operating pressure The valve may be used for a maximum pressure of 350 bar If the maximum pressure is exceeded there is a risk of damage to the valve Exceeding the pressure value may cause the...

Страница 9: ...ool in the event of loss of solenoid function or loss of electrical supply to the solenoid coils to achieve the safe position of the actuated mechanism The use of emergency manual control is limited b...

Страница 10: ...nge T4 135 C 10 W C 30 70 T5 100 C 30 55 T6 85 C 30 45 IP68 test conditions product submerged 1m under water for 1 hour 4 4 Basic technical parameters The valve is designed for common hydraulic workin...

Страница 11: ...0 4350 2180 0 10 20 30 40 50 2 6 5 3 7 9 13 2 15 9 10 6 60 725 150 200 50 300 5800 400 1450 100 5080 350 3630 250 2 1 3 5 4 1 2 3 4 5 6 6 1 3 5 10 20 30 40 50 2 6 5 3 8 0 10 6 13 2 15 9 10 20 30 40 50...

Страница 12: ...B2 chamber B2 C 10 2 B3 chamber B3 C 10 3 B4 chamber B4 C 10 4 High performance Spool connection according to connection table Supply power DC voltage 01200 12 V DC 0 75 A 02400 24 V DC 0 39 A 04800...

Страница 13: ...t Cut the packaging with scissors and carefully remove the valve from the packaging Unpack the valve in a clean place and prevent contamination of the valve The packaging is made of PE and can be easi...

Страница 14: ...der the head of the ground screw located next to the terminal block and screw in and tighten the ground screw M3 with an inbus wrench a 2 5 mm to a torque of 1 2 0 2 Nm Coils with DC power supply and...

Страница 15: ...ply Nominal supply voltage Winding resistance at t 20 C Nominal current Limit current Bipolar diode Nominal input power UN V DC R20 IN A IG A UZ V PN W EX18 046 10W 12V DC 12 16 1 0 750 0 65 36 8 9 EX...

Страница 16: ...22 Page 16 www argo hytos com Chamber B2 min for side channel space for the radial bore AXIAL BORE REAMED Chamber B3 min for side channel space for the radial bore AXIAL BORE min for side channel spac...

Страница 17: ...d seals are fitted to the valve housing Also verify that the valve and chamber surfaces are not damaged or contaminated Before installing the valve we recommend lightly lubricating the housing seals w...

Страница 18: ...ion plate and that electrical supply cables are correctly connected The valve is not to be adjusted Test operation should be conducted without the pressence of an explosive atmosphere After the hydrau...

Страница 19: ...contaminated objects in the vicinity cleaned or disposed of Contaminated objects and residues of leaked working fluid must be disposed of in accordance with the applicable environmental regulations FI...

Страница 20: ...lve housing Remove residual working fluid from the dismantled defective valveand package it to prevent mechanical damage and contamination of the area outside the package during transport Send the pac...

Страница 21: ...2 and 3 7 8 Spare parts supplied 1 2 5 4 3 1 6 Overview and designation of coils order numbers Coils with DC power supply cable grommet without cable Designation on the coil PN W UN V DC Designation...

Страница 22: ...composition Length of storage A Polyurethane AU Polyester urethane rubber 5 years B NBR Butadiene acrylonitrile rubber 7 years C FKM FPM Viton Fluoroelastomer 10 years C VMQ Vinyl methyl silicone rub...

Страница 23: ...2022 vydan v robcem D le it P ed pou it m v robku si pozorn p e t te n vod N vod k pou it uchovejte pro budouc pot ebu P i ztr t n vodu k pou it z sk te nov na webov ch st nk ch v robce ARGO HYTOS ww...

Страница 24: ...N vod k pou it _SD2EX B2 B3 B4 _14064_1cz_05 2022 Strana 2 www argo hytos com Prohl en o shod...

Страница 25: ...N vod k pou it _SD2EX B2 B3 B4 _14064_1cz_05 2022 Strana 3 www argo hytos com...

Страница 26: ...N vod k pou it _SD2EX B2 B3 B4 _14064_1cz_05 2022 Strana 4 www argo hytos com...

Страница 27: ...10 4 5 Pracovn kapalina 10 4 6 Charakteristiky ventilu 10 4 7 Pou it p edpisy a normy 11 5 Modifikace v robku 12 6 C lov skupina u ivatel 13 7 N vod k pou it len n podle f z ivota v robku 13 7 1 P ep...

Страница 28: ...1bar 0 1MPa NEBEZPE Sign ln slovo kombinovan s v stra nou zna kou pou van k signalizaci bezprost edn hroz c nebezpe n situace kter m e m t za n sledek smrt nebo v n zran n V STRAHA Sign ln slovo kombi...

Страница 29: ...T5 T6 Gb Ex eb mb IIC T4 T5 T6 Gb lI 2D Ex tb IIIC T135 C T100 C T85 C Db Ex tb IIIC T135 C T100 C T85 C Db Oblasti pou it 2 2 Pr chodka kabelu Pr chodka kabelu je samostatn certifikovanou sou st s c...

Страница 30: ...a materi l t sn n hroz po kozen t sn n a nik pracovn kapaliny VAROV N Povrchov teplota ventilu Povrchov teplota ventilu m e vlivem teploty pracovn kapaliny a tlakov ch ztr t ve ventilu p em n n ch na...

Страница 31: ...r ty funkce elektromagnetu nebo p i v padku elektrick ho nap jen c vek pro dosa en bezpe n polohy ovl dan ho mechanismu Pou it ru n ho nouzov ho ovl d n je omezeno maxim ln m tlakem v kan lu T 1 25 ba...

Страница 32: ...30 55 T6 85 C 30 45 IP68 podm nky testu v robek pono en 1 m pod vodou po dobu 1 hodiny 4 4 Z kladn technick parametry Ventil je ur en pro obvykl hydraulick pracovn kapaliny miner ln oleje v konov ch...

Страница 33: ...7 9 13 2 15 9 10 6 60 725 150 200 50 300 5800 400 1450 100 5080 350 3630 250 2 1 3 5 4 1 2 3 4 5 6 6 1 3 5 10 20 30 40 50 2 6 5 3 8 0 10 6 13 2 15 9 10 20 30 40 50 60 0 1 50 290 4 40 580 7 30 4 1 2 3...

Страница 34: ...2 B3 komora B3 C 10 3 B4 komora B4 C 10 4 High performance Propojen oup tka viz tabulka propojen Nap jen c vky DC nap t 01200 12 V DC 0 75 A 02400 24 V DC 0 39 A 04800 48 V DC 0 19 A 11000 110 V DC 0...

Страница 35: ...st typu ventilu na identifika n m t tku Obal rozst ihn te n kami a opatrn vyjm te ventil z obalu Ventil rozbalujte na ist m m st a zabra te kontaminaci ventilu Obal je vyroben z PE a m e b t lehce kon...

Страница 36: ...abelov o ko zemn c ho vodi e navl kn te pod hlavu zemn c ho roubu um st n ho vedle svorkovnice a zemnic roub M3 za roubujte a dot hn te pomoc inbus kl e a 2 5 mm momentem 1 2 0 2 Nm Elektrick obvod el...

Страница 37: ...n m Jmen nap jec nap t Odpor vinut p i t 20 C Jmen proud Limitn proud Bipol rn dioda Jmen p kon UN V DC R20 IN A IG A UZ V PN W EX18 046 10W 12V DC 12 16 1 0 750 0 65 36 8 9 EX18 046 10W 24V DC 24 61...

Страница 38: ...hytos com Komora B2 min for side channel prostor pro radi ln pr vrt AXIAL PR VRT Hl OPRACOV N Hl OPRACOV N Hl OPRACOV N Komora B3 min for side channel prostor pro radi ln pr vrt AXIAL PR VRT min for...

Страница 39: ...u nasazen nepo kozen t sn n Rovn prov te e povrch ventilu a komory nen po kozen a zne i t n P ed mont ventilu doporu ujeme lehce namazat t sn n pouzdra mazac m tukem nebo pracovn kapalinou M rn m tlak...

Страница 40: ...o obvodu do provozu zkontrolujte spr vn uta en ventilu v komo e bloku a spr vn zapojen kabel elektrick ho nap jen Ventil se nese izuje Zku ebn provoz by m l prob hat bez p tomnosti v bu n atmosf ry Po...

Страница 41: ...nebo zlikvidov ny Kontaminovan p edm ty a zbytky unikl pracovn kapaliny mus b t zlikvidov ny v souladu s platn mi ekologick mi p edpisy PRVN POMOC Zasa en elektrick m proudem Vypn te ihned zdroj elek...

Страница 42: ...ou k na pouzdru ventilu Z demontovan ho vadn ho ventilu odstra te zbytkovou pracovn kapalinu a zabalte jej tak aby nedo lo k mechanick mu po kozen a kontaminaci prostoru mimo obal b hem p epravy Zabal...

Страница 43: ...a c vce PN W UN V AC Ozna en ARGO HYTOS Objednac slo EX18 046 10W 110V AC 3M 10 110 EX22 46 11050 10W3M B 42139600 EX18 046 10W 110V AC 8M 10 110 EX22 46 11050 10W8M B 42139800 EX18 046 10W 230V AC 3M...

Страница 44: ...zvu podle ISO 1629 Chemick slo en D lka skladov n A Polyuretan AU Polyester uretanov pry 5 let B NBR Butadienakrylonitrilov kau uk 7 let C FKM FPM Viton Fluoroelastomer 10 let C VMQ Vinil metyl silik...

Отзывы: