All of the above activities related to this valve, in particular installation and connection to the hydraulic circuit, require specialist technical knowledge 
and experience in the field of hydraulics. The minimum level of competence required is CETOP level 2. This level is generally defined as performing a 
variety of activities that require an understanding of technical factors and contexts. This may lead to the need for correct interpretation (e.g. 
tolerances, operating methods) or the application of various non-repetitive procedures. This may require the performance of checks, simple analysis 
and diagnostics, and the ability to react to changes in an operational manner. Teamwork is often necessary.
The connection of solenoid coils to the supply voltage must only be carried out by persons with the appropriate electrical qualifications.
All operations must be carried out with responsibility for correctness and quality, as this is a dangerous area of product use.

It is forbidden for the following persons to carry out any activities related to this product:

 › minors (the exception is practical training of pupils under the professional supervision of a teacher)
 › without established professional competence
 › under the influence of alcohol and/or drugs
 › patients whose medical condition could affect safety (reduced attention and ability to react in time, excessive fatigue)
 › under the influence of drugs that have a demonstrable effect on attention and timeliness 
 › allergic to hydraulic working fluids

6. Target user group

The valve is packaged in vacuum shrink-wrapped PE film and protected against moisture and dust as standard. An identification label is affixed to the 
packaging.The products should only be stored for the necessary time at a temperature of 0 to +30 °C in a dry place with a relative humidity of up to 
65 %. After extended periods of storage, we recommend checking the product for corrosion damage, replacing seal at the base of the body and 
flushing the product with clean oil before connecting it to the hydraulic circuit.

Check that the valve type on the identification plate is correct. 
Cut the packaging with scissors and carefully remove the valve from the packaging. 
Unpack the valve in a clean place and prevent contamination of the valve. 
The packaging is made of PE and can be easily contaminated with residual hydraulic oil from the valve. 
Dispose of the packaging in accordance with applicable environmental regulations. 

The mounting position of the valve is arbitrary. However, if vibrations or shocks are applied to the valve during operation, they must not be applied in 
the direction of the spool axis. 

7. Operating instructions broken down by product life stage

7.1 Transportation and storage of the product

7.2 Installation of the product

 › Coils with AC power supply and rectifier are supplied with only the cable connected. Also, DC powered coils can be supplied by the manufacturer  

  with the cable attached upon request. If the directional control valve coils do not have a power cable connected, proceed as follows:

 ›  A 6 to 8 mm outer diameter cable must be used to connect the coils to the power supply. If using a different type of grommet, follow the  

 

  grommet manufacturer‘s recommendations when selecting the cable diameter.

 › Use a cable with sufficient insulation temperature class. For coil temperature class T4 this must be a cable with a minimum insulation temperature  

  resistance of +105 °C (+221 °F), for temperature classes T5 and T6 a cable with a temperature resistance of +90 °C (+194 °F). Furthermore, the    

  cable should be sufficiently protected against damage with respect to environmental conditions, e.g. resistant to mechanical damage or to the    

  effect of chemicals. Using an inbus wrench s=3, loosen the four M4x35 DIN 912 terminal cover screws. Carefully remove the cover . Do not  

 

  damage the cover seal (O-ring 45x2). 

4x screw M4x35 DIN 912

terminal lid

CAUTION

Slippery valve surface

 

The valve contains a small amount of residual oil after a hydraulic function test carried out by the manufacturer. 
If the surface of the unpacked valve is contaminated with oil, remove the oil using a cleaning cloth. A slippery 
valve surface can cause the valve to fall during handling and cause minor injury or damage to the valve.

7.2.1 Electrical connection of coils

 › Unscrew the grommet nut (5) of the cable grommet with the wrench a = 24, remove and check the grommet seal (2) for damage. 
 › Thread the cable through the removed grommet parts (2, 3, 5) and the grommet in the terminal lid (1).

Содержание SD2EX-B2

Страница 1: ...E DESIGNED FOR USE IN EXPLOSIVE ATMOSPHERES SD2EX B2 SD2EX B3 SD2EX B4 EN The following is the authorised translation of original operating instruction SD2EX B2 B3 B4 no 14054_1cz_03 2022 issued by th...

Страница 2: ...Subject to change_SD2EX B2 B3 B4 _14064_1en_05 2022 Page 2 www argo hytos com Prohl en o shod...

Страница 3: ...Subject to change_SD2EX B2 B3 B4 _14064_1en_05 2022 Page 3 www argo hytos com...

Страница 4: ...Subject to change_SD2EX B2 B3 B4 _14064_1en_05 2022 Page 4 www argo hytos com...

Страница 5: ...ace protection against corrosion 9 4 4 Basic technical parameters 10 4 5 Working fluid 10 4 6 Valve characteristics 10 4 7 Legislation and standards 11 5 Product modifications 12 6 Target group of use...

Страница 6: ...ctice the unit used is bar 1bar 0 1MPa DANGER Signal word combined with a warning sign used to signify that a dangerous situation which could result in death or serious injury is imminent WARNING Sign...

Страница 7: ...C T100 C T85 C Db Ex tb IIIC T135 C T100 C T85 C Db Area of aapplication 2 2 Cable grommet The cable grommet is a separately certified component with ATEX and IECEx certification I M2 Ex eb I Mb II 2...

Страница 8: ...aximum operating pressure The valve may be used for a maximum pressure of 350 bar If the maximum pressure is exceeded there is a risk of damage to the valve Exceeding the pressure value may cause the...

Страница 9: ...ool in the event of loss of solenoid function or loss of electrical supply to the solenoid coils to achieve the safe position of the actuated mechanism The use of emergency manual control is limited b...

Страница 10: ...nge T4 135 C 10 W C 30 70 T5 100 C 30 55 T6 85 C 30 45 IP68 test conditions product submerged 1m under water for 1 hour 4 4 Basic technical parameters The valve is designed for common hydraulic workin...

Страница 11: ...0 4350 2180 0 10 20 30 40 50 2 6 5 3 7 9 13 2 15 9 10 6 60 725 150 200 50 300 5800 400 1450 100 5080 350 3630 250 2 1 3 5 4 1 2 3 4 5 6 6 1 3 5 10 20 30 40 50 2 6 5 3 8 0 10 6 13 2 15 9 10 20 30 40 50...

Страница 12: ...B2 chamber B2 C 10 2 B3 chamber B3 C 10 3 B4 chamber B4 C 10 4 High performance Spool connection according to connection table Supply power DC voltage 01200 12 V DC 0 75 A 02400 24 V DC 0 39 A 04800...

Страница 13: ...t Cut the packaging with scissors and carefully remove the valve from the packaging Unpack the valve in a clean place and prevent contamination of the valve The packaging is made of PE and can be easi...

Страница 14: ...der the head of the ground screw located next to the terminal block and screw in and tighten the ground screw M3 with an inbus wrench a 2 5 mm to a torque of 1 2 0 2 Nm Coils with DC power supply and...

Страница 15: ...ply Nominal supply voltage Winding resistance at t 20 C Nominal current Limit current Bipolar diode Nominal input power UN V DC R20 IN A IG A UZ V PN W EX18 046 10W 12V DC 12 16 1 0 750 0 65 36 8 9 EX...

Страница 16: ...22 Page 16 www argo hytos com Chamber B2 min for side channel space for the radial bore AXIAL BORE REAMED Chamber B3 min for side channel space for the radial bore AXIAL BORE min for side channel spac...

Страница 17: ...d seals are fitted to the valve housing Also verify that the valve and chamber surfaces are not damaged or contaminated Before installing the valve we recommend lightly lubricating the housing seals w...

Страница 18: ...ion plate and that electrical supply cables are correctly connected The valve is not to be adjusted Test operation should be conducted without the pressence of an explosive atmosphere After the hydrau...

Страница 19: ...contaminated objects in the vicinity cleaned or disposed of Contaminated objects and residues of leaked working fluid must be disposed of in accordance with the applicable environmental regulations FI...

Страница 20: ...lve housing Remove residual working fluid from the dismantled defective valveand package it to prevent mechanical damage and contamination of the area outside the package during transport Send the pac...

Страница 21: ...2 and 3 7 8 Spare parts supplied 1 2 5 4 3 1 6 Overview and designation of coils order numbers Coils with DC power supply cable grommet without cable Designation on the coil PN W UN V DC Designation...

Страница 22: ...composition Length of storage A Polyurethane AU Polyester urethane rubber 5 years B NBR Butadiene acrylonitrile rubber 7 years C FKM FPM Viton Fluoroelastomer 10 years C VMQ Vinyl methyl silicone rub...

Страница 23: ...2022 vydan v robcem D le it P ed pou it m v robku si pozorn p e t te n vod N vod k pou it uchovejte pro budouc pot ebu P i ztr t n vodu k pou it z sk te nov na webov ch st nk ch v robce ARGO HYTOS ww...

Страница 24: ...N vod k pou it _SD2EX B2 B3 B4 _14064_1cz_05 2022 Strana 2 www argo hytos com Prohl en o shod...

Страница 25: ...N vod k pou it _SD2EX B2 B3 B4 _14064_1cz_05 2022 Strana 3 www argo hytos com...

Страница 26: ...N vod k pou it _SD2EX B2 B3 B4 _14064_1cz_05 2022 Strana 4 www argo hytos com...

Страница 27: ...10 4 5 Pracovn kapalina 10 4 6 Charakteristiky ventilu 10 4 7 Pou it p edpisy a normy 11 5 Modifikace v robku 12 6 C lov skupina u ivatel 13 7 N vod k pou it len n podle f z ivota v robku 13 7 1 P ep...

Страница 28: ...1bar 0 1MPa NEBEZPE Sign ln slovo kombinovan s v stra nou zna kou pou van k signalizaci bezprost edn hroz c nebezpe n situace kter m e m t za n sledek smrt nebo v n zran n V STRAHA Sign ln slovo kombi...

Страница 29: ...T5 T6 Gb Ex eb mb IIC T4 T5 T6 Gb lI 2D Ex tb IIIC T135 C T100 C T85 C Db Ex tb IIIC T135 C T100 C T85 C Db Oblasti pou it 2 2 Pr chodka kabelu Pr chodka kabelu je samostatn certifikovanou sou st s c...

Страница 30: ...a materi l t sn n hroz po kozen t sn n a nik pracovn kapaliny VAROV N Povrchov teplota ventilu Povrchov teplota ventilu m e vlivem teploty pracovn kapaliny a tlakov ch ztr t ve ventilu p em n n ch na...

Страница 31: ...r ty funkce elektromagnetu nebo p i v padku elektrick ho nap jen c vek pro dosa en bezpe n polohy ovl dan ho mechanismu Pou it ru n ho nouzov ho ovl d n je omezeno maxim ln m tlakem v kan lu T 1 25 ba...

Страница 32: ...30 55 T6 85 C 30 45 IP68 podm nky testu v robek pono en 1 m pod vodou po dobu 1 hodiny 4 4 Z kladn technick parametry Ventil je ur en pro obvykl hydraulick pracovn kapaliny miner ln oleje v konov ch...

Страница 33: ...7 9 13 2 15 9 10 6 60 725 150 200 50 300 5800 400 1450 100 5080 350 3630 250 2 1 3 5 4 1 2 3 4 5 6 6 1 3 5 10 20 30 40 50 2 6 5 3 8 0 10 6 13 2 15 9 10 20 30 40 50 60 0 1 50 290 4 40 580 7 30 4 1 2 3...

Страница 34: ...2 B3 komora B3 C 10 3 B4 komora B4 C 10 4 High performance Propojen oup tka viz tabulka propojen Nap jen c vky DC nap t 01200 12 V DC 0 75 A 02400 24 V DC 0 39 A 04800 48 V DC 0 19 A 11000 110 V DC 0...

Страница 35: ...st typu ventilu na identifika n m t tku Obal rozst ihn te n kami a opatrn vyjm te ventil z obalu Ventil rozbalujte na ist m m st a zabra te kontaminaci ventilu Obal je vyroben z PE a m e b t lehce kon...

Страница 36: ...abelov o ko zemn c ho vodi e navl kn te pod hlavu zemn c ho roubu um st n ho vedle svorkovnice a zemnic roub M3 za roubujte a dot hn te pomoc inbus kl e a 2 5 mm momentem 1 2 0 2 Nm Elektrick obvod el...

Страница 37: ...n m Jmen nap jec nap t Odpor vinut p i t 20 C Jmen proud Limitn proud Bipol rn dioda Jmen p kon UN V DC R20 IN A IG A UZ V PN W EX18 046 10W 12V DC 12 16 1 0 750 0 65 36 8 9 EX18 046 10W 24V DC 24 61...

Страница 38: ...hytos com Komora B2 min for side channel prostor pro radi ln pr vrt AXIAL PR VRT Hl OPRACOV N Hl OPRACOV N Hl OPRACOV N Komora B3 min for side channel prostor pro radi ln pr vrt AXIAL PR VRT min for...

Страница 39: ...u nasazen nepo kozen t sn n Rovn prov te e povrch ventilu a komory nen po kozen a zne i t n P ed mont ventilu doporu ujeme lehce namazat t sn n pouzdra mazac m tukem nebo pracovn kapalinou M rn m tlak...

Страница 40: ...o obvodu do provozu zkontrolujte spr vn uta en ventilu v komo e bloku a spr vn zapojen kabel elektrick ho nap jen Ventil se nese izuje Zku ebn provoz by m l prob hat bez p tomnosti v bu n atmosf ry Po...

Страница 41: ...nebo zlikvidov ny Kontaminovan p edm ty a zbytky unikl pracovn kapaliny mus b t zlikvidov ny v souladu s platn mi ekologick mi p edpisy PRVN POMOC Zasa en elektrick m proudem Vypn te ihned zdroj elek...

Страница 42: ...ou k na pouzdru ventilu Z demontovan ho vadn ho ventilu odstra te zbytkovou pracovn kapalinu a zabalte jej tak aby nedo lo k mechanick mu po kozen a kontaminaci prostoru mimo obal b hem p epravy Zabal...

Страница 43: ...a c vce PN W UN V AC Ozna en ARGO HYTOS Objednac slo EX18 046 10W 110V AC 3M 10 110 EX22 46 11050 10W3M B 42139600 EX18 046 10W 110V AC 8M 10 110 EX22 46 11050 10W8M B 42139800 EX18 046 10W 230V AC 3M...

Страница 44: ...zvu podle ISO 1629 Chemick slo en D lka skladov n A Polyuretan AU Polyester uretanov pry 5 let B NBR Butadienakrylonitrilov kau uk 7 let C FKM FPM Viton Fluoroelastomer 10 let C VMQ Vinil metyl silik...

Отзывы: