![Argo-Hytos RPERX3-06 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/argo-hytos/rperx3-06/rperx3-06_operating-instructions-manual_2967779011.webp)
Subject to change_RPERX3-06_14095_1en_03/2022
Page 11
www.argo-hytos.com
4.7 Legislation and standards:
ČSN EN ISO 4413
Hydraulics - General rules and safety requirements for hydraulic systems and their components
Other regulations and standards used:
ČSN ISO 6403
Hydrostatic drives. Valves for flow and pressure control. Test methods
ČSN ISO 4411
Measurement of the characteristics Δp = function (Q) of hydraulic valves
ČSN EN ISO 9001
Quality management systems
ČSN EN ISO 12100
Machine safety / risk analysis
Directive 2006/42/EU
on machinery / used chapters: 1.7.4 Instructions for use, Annex III CE marking
ČSN EN 82079-1
Preparation of instruction manuals - Structure, content and presentation / Part 1: General principles and detailed requirements
5. Product modification
Ordering code
An overview of possible valve modifications is described in the ordering key.
The number of spool positions, the spool connection and the type of emergency control and the electrical parameters of the coil cannot be subse-
quently changed by the user. In the case of a valve with a 10 W coil, the coil surface temperature and the application for the temperature class can be
affected by adjusting the ambient temperature (see 4.4 Ambient temperature range for each class).
The coils with AC power supply and built-in rectifier are supplied with only the cable attached, with optional lengths of 3 and 8 m as standard.
R30
Spool Symbols
Type Symbol Interpositions
Type Symbol Interpositions
RPERX3-06 / / - B
2
3
01200
02400
04800
11000
11050
23050
A19
B19
A4
A6
*EAEU= Eurasian Economic Union, certificate according to TR TS 012/2011 valid for Russian Federation, Belarus, Armenia, Kazakhstan and Kyrgyzstan.
**For two-position directional control valves with one coil: the lever is always located between the valve body and the coil.
Certifications of valve
ATEX, IECEx
IECEx for Australia and New Zealand
EAC for EAEU* States
No designation
A
E
Number of valve positions
two positions
three positions
Explosion proof, 4/2 and 4/3,
directional control valve,
solenoid operated, with lever
override
Valve size
Spool symbols
according to the connection table
DC voltage
(Standard delivery without cable grommet)
12 V DC / 0,75 A
24 V DC / 0,39 A
48 V DC / 0,19 A
110 V DC / 0,094 A
AC voltage 50/60 Hz
(Standard delivery with non-removable cable)
110 V AC / 0,112 A
230 V AC / 0,052 A
Surface treatment
zinc-coated (ZnNi), ISO 9227 (520 h)
No designation
Seal material
NBR
Manual lever and position
of override actuating section***
standard, lever on side A pointing up
standard, lever on side B pointing up
Cable length
without cable
3 m
8 m
No designation
(only for DC)
3 (AC and DC version)
8 (AC and DC version)
Temperature class - solenoid nominal input power
ClassT4 - 10 W
Class T6 (T5) - 10 W
In directional control valves with two control solenoids, the
solenoids are switched simultaneously.
Содержание RPERX3-06
Страница 2: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 2 www argo hytos com ...
Страница 3: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 3 www argo hytos com ...
Страница 4: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 4 www argo hytos com ...
Страница 21: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 2 www argo hytos com ...
Страница 22: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 3 www argo hytos com ...
Страница 23: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 4 www argo hytos com ...