HARDWARE INSTALLATION

5

If the system will use only a single global indicator, attach the LED to 

the two pins of the global activity/fault connector. The global fault pin 

pair connector is the overall activity/fault signal. 

LED

Normal Status

Problem Indication

Activity 

(HDD) LED

When the activity (HDD) 

LED is illuminated, there 

is I/O activity on that disk 

drive. When the activity 

LED is dark, there is no 

activity on that disk drive.

N/A

Fault LED

When the fault LED is 

solid illuminated, there is 

no disk present and When 

the fault LED is off, that 

disk is present and status 

is normal.  

 

When the "Identify Drive" 

is selected, the selected 

drive fault LED will blank.

When the fault LED is slow 

blinking (2 times/sec), 

that indicate disk drive has 

failed and should be hot-

swapped immediately.  

 

When the activity (HDD) 

LED is illuminated and fault 

LED is fast blinking (10 

times/sec) that indicate 

there is rebuilding activity 

on the disk drive.

A: Individual Fault LED and Global Activity/Fault Indicator Con-

nector

The 6Gb/s SATA RAID controller provides the connector for fault/

activity LED. Connect the cables for the fault/activity LEDs and the 

respective connector on the 6Gb/s SATA RAID controller. 

The following table is the fault/activity LED signal behavior.

Содержание ARC-1203-2i

Страница 1: ...ARC 1203 2 ports PCIe 2 0 to 6Gb s SATA RAID Controllers 6Gb s SATA RAID Cards Installation Guide Version 1 0 Issue Date October 2016 Website http www areca com tw...

Страница 2: ...cord Remove the sys tem s cover For the instructions please see the computer system documentation Step 3 Install the PCIe 6Gb s SATA RAID Cards To install the 6Gb s SATA RAID controller remove the mou...

Страница 3: ...cages or SATA drives in the computer chassis Loading drives to the drive tray if cages are installed Be sure that the power is connected to the individual drives Step 5 Connect the SATA Cable ARC 1203...

Страница 4: ...activity status The global indicator connector is used by the serv er desktop system global indicator LED The following electronics schematic is the 6Gb s SATA RAID controller logical of fault activi...

Страница 5: ...ault LED is off that disk is present and status is normal When the Identify Drive is selected the selected drive fault LED will blank When the fault LED is slow blinking 2 times sec that indicate disk...

Страница 6: ...orms you the disk array s current operating status at a glance The LCD configuration is described in a separate manual RAID Card_LCD manual The LCD housed in a 5 inch half height or 3 5 inch canister...

Страница 7: ...oxy Server The ARC 1203 2I firmware has embedded the web browser McRAID storage manager ArcHTTP proxy server will launch the web browser McRAID storage manager It provides all of the creation manageme...

Страница 8: ...oller see the Chapter 6 Web Browser Based Configuration of the user manual Method 3 Front LCD Panel with Keypad Optional You can use LCD front panel and keypad function to simply cre ate the RAID volu...

Страница 9: ...pose Port 14 pin header 6 SCN1 SATA Port 1 CH2 SATA III 7 SCN2 SATA Port 0 CH1 SATA III 8 D3 Fault Activity LED for CH1 Bi color DIP 9 D4 Fault Activity LED for CH2 Bi color DIP Table 1 ARC 1203 2i co...

Страница 10: ...Figure 5 Connect to LCD Status Panel Figure 4 ARC 1203 2i individual Fault Activity LED for each channel drive and global indicator connector for computer case...

Отзывы: