background image

User’s manual – A

REBO

S Bench drill 500W 

 

 

 

 

Break long drilling chips by interrupting the drilling process by briefly turning back the turning 

wheel. There is a risk of injury due to long drilling chips.  

 

Keep handles dry, clean and free of oil and grease. Greasy, oily handles are slippery and lead 

to loss of control.  

 

Use fixtures to clamp the workpiece. Do not machine workpieces that are too small to clamp. 

If you hold the workpiece by hand, you cannot secure it sufficiently against twisting and 

injure yourself.  

 

Turn off the power tool immediately if the insert tool blocks. The insert tool will lock if: the 

power tool is overloaded or it cants in the workpiece to be machined.  

 

Do not touch the insert tool after machining until it has cooled down. The insert tool 

becomes very hot when working.  

 

Inspect the cable regularly and have a damaged cable repaired only by an authorised service 

centre. Replace damaged extension cables. This will ensure that the safety of the power tool 

is maintained.  

 

Keep the unused power tool safe. The storage area must be dry and lockable. This prevents 

the power tool from being damaged during storage or from being operated by inexperienced 

persons.  

 

Never leave the tool before it has come to a complete stop. Trailing insert tools can cause 

injuries.  

 

Do not use the power tool with a damaged cable. Do not touch the damaged cable and 

disconnect the power plug if the cable is damaged during work. Damaged cables increase the 

risk of electric shock. 

1.4 Precautions against accident hazards

 

 

Do not look directly into the laser beam with an unprotected eye. 

 

 

Never look directly into the beam path. 

 

Never point the laser beam at reflective surfaces, persons or animals. Even a low-power laser 

beam can cause damage to the eye.  

 

Caution!

 If procedures other than those specified here are used, this can result in dangerous 

beam exposure.  

 

If the cross-cut saw is not used for an extended period of time, the batteries should be 

removed.  

 

Do not replace the laser with another type of laser.  

 

Repairs to the laser may only be carried out by the manufacturer of the laser or an 

authorized

     

 

1.5 Residual risks 

 

The power tool is built according to the state of the art and the recognized safety regulations. 

Nevertheless, individual residual risks may occur during operation.  

 

Danger to health from electricity if incorrect electrical connection cables are used.  

 

Furthermore, despite all precautions taken, there may be non-obvious residual risks.  

 

Residual risks can be minimized if the "Safety Instructions" and the "Intended Use" as well as 

the operating instructions are observed in their entirety.  

 

Do not stress the machine unnecessarily: excessive pressure during sawing will quickly 

damage the saw blade. This can lead to a reduction in machine performance during 

processing and a reduction in cutting accuracy.  

 

Avoid accidental start-up of the machine: the operating button must not be pressed when 

inserting the plug into the socket.  

 

Use the tool recommended in this manual. This will ensure that your saw performs optimally. 

 

Содержание AR-HE-TBM500

Страница 1: ...User s manual AREBOS Bench drill 500W 1 Bench drill 500 W AR HE TBM500 Please follow all security measures in this user s manual to ensure a secure use Thank you for trusting AREBOS...

Страница 2: ...4 3 Clamping the drill bit 12 4 4 Spindle speed 12 4 5 Clamping the workpiece 13 4 6 Test run 14 4 7 Maintenance 16 5 Intended Use 16 6 Putting into service 17 6 1 Before use 17 6 2 Safety precaution...

Страница 3: ...Safety instructions 1 1 Explanation of the symbols By means of a CE marking it can be recognized that a product complies with the legal requirements of European legal standards and therefore may be t...

Страница 4: ...rom electric shock Avoid body contact with earthed parts e g pipes radiators electric cookers refrigerators Keep other persons away Do not allow other persons especially children to touch the power to...

Страница 5: ...ure that they are functioning properly and in accordance with their intended purpose Check that the moving parts function properly and are not jammed or that parts are damaged All parts must be proper...

Страница 6: ...ing work Damaged cables increase the risk of electric shock 1 4 Precautions against accident hazards Do not look directly into the laser beam with an unprotected eye Never look directly into the beam...

Страница 7: ...chuck holder B16 Drill chuck 1 5 16 mm Size drilling table 164 x 162 mm Angle adjustment 45 0 45 Drilling depth 50 mm Column diameter 46 mm Height 590 mm Footprint 298 x 190 mm Weight 14 5 kg Laser c...

Страница 8: ...User s manual AREBOS Bench drill 500W 8 3 Scope of delivery...

Страница 9: ...s if present Check that the scope of delivery is complete Check the device and accessories for transport damage If possible keep the packaging until the end of the warranty period Attention The device...

Страница 10: ...User s manual AREBOS Bench drill 500W 10...

Страница 11: ...User s manual AREBOS Bench drill 500W 11...

Страница 12: ...e see 2 Technical data Fig 6 by loosening the cross screw The wing screw is loosened by hand between the motor and the switch for the laser so that the belt relaxes The belt can now easily be set to t...

Страница 13: ...User s manual AREBOS Bench drill 500W 13 4 5 Clamping the workpiece...

Страница 14: ...User s manual AREBOS Bench drill 500W 14 4 6 Test run...

Страница 15: ...User s manual AREBOS Bench drill 500W 15...

Страница 16: ...fety instructions This device may only be used as intended The manufacturer cannot be held responsible for any damage resulting from non compliance with the provisions of the generally applicable regu...

Страница 17: ...tention Keep body parts and clothes away from moving parts of the device 6 2 Safety precautions when handling the machine Use protective equipment that is tailored to your needs Wear a hair net for lo...

Страница 18: ...damaged parts Attention If the connecting cable of this device is damaged it must be replaced by the manufacturer or its customer service or a similarly qualified person in order to avoid hazards Rep...

Страница 19: ...children There is a risk of suffocation 9 2 Disposal of waste equipment Equipment must be disposed of in accordance with the rules and regulations of the local waste disposal 9 3 Meaning of the dustbi...

Страница 20: ...ication not allowed by us this declaration loses ist validity Tested acc to EU Standard EN 55014 1 2006 A1 A2 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55014 2 2015 EN 61029 1 2009 A11 Date Manufacturer...

Отзывы: