background image

User’s Manual –

 A

REBO

S Domestic waterworks 1000 W 

 

 
 

substances, etc. in the pumping liquid for a long time. Since the pumping liquids may 
contain corrosive chemical substances, it is of particular importance to prevent their 
action on the material of the pump body. 

 

Sand and stones in the pumping water can cause the pump to wear out quickly and 
reduce its effective performance. Therefore, the installation of a filter is necessary. 

 

If too much pump water flooded the area to be irrigated due to your own fault, you must 
take a number of protective measures (such as the installation of a water disposal 
device, an alarm device, a reserve pump, a water tank, etc.). In any case, the 
manufacturer is not responsible for any damage or loss caused thereby. 

 

 

This pump is not suitable for the transport of drinking water! 

 

Only use extension cords intended for outdoor use. Always unroll cable drums 
completely. 

 

Protect cables from heat, oil and sharp edges. 

 

Only use the device and extension cable in a technically perfect condition! Damaged 
devices must not be operated. 

 

Never carry the pump by the cable. 

 

The power supply must be in accordance with the specifications given on the product. If 
necessary, ask your energy supply company for the necessary connection conditions. If 
the pump and power cord do not meet the conditions, do not connect the pump! 

 

Never remove the plug or shorten the cable. Keep the connections (plug and socket) dry. 

 

Unauthorized modifications or changes to the device are prohibited. 

 

When the garden pump is in operation, the water outlet (such as the tap or sprinkler 
system) must be open to allow air to escape from the hose. If the water outlet is closed, 
the pump may be damaged by overheating after more than 5 minutes of operation. 

 

Prior to use, always visually inspect to see if the pump, especially the power cord and 
plug, is damaged. 

 

Never touch the power plug with wet hands. 

 

It is absolutely forbidden to reach into the opening of the pump with your hands when 
the device is connected to the mains. 

 

A direct connection to the public drinking water network for drinking water supply is not 
permitted. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание AR-HE-HWW1000

Страница 1: ...User s Manual AREBOS Domestic waterworks 1000 W 1 Domestic waterworks 1000 W AR HE HWW1000 User s Manual Please follow all security measures in this user s manual to ensure a secure use...

Страница 2: ...ns 6 5 Assembly 7 5 1 General 7 5 2 Connect suction line 7 5 3 Connect pressure line 8 5 4 Fill the pump 8 6 Operation 8 7 Troubleshooting 9 8 Cleaning maintenance and storage 13 8 1 General cleaning...

Страница 3: ...iance To install the unit safely and correctly please read the operating instructions before you start Check the unit for any damage that may have occurred during transport Immediately report any dama...

Страница 4: ...n using the domestic waterworks can lead to serious injuries This device is not intended to be used by children and persons with reduced physical mental or psychological abilities and by persons witho...

Страница 5: ...vice and extension cable in a technically perfect condition Damaged devices must not be operated Never carry the pump by the cable The power supply must be in accordance with the specifications given...

Страница 6: ...er components aggressive corrosive explosive or gassing chemicals or liquids water and food or drink liquids above 95 F 35 C 3 Function The pumps have a maintenance free motor with thermal overload pr...

Страница 7: ...essure 5 2 Connect suction line Select the length of the suction line so that the domestic waterworks cannot run dry The suction line must always be at least 11 8 in 30 cm below the water surface The...

Страница 8: ...e the intake hose must first be equipped as described below 1 Check valve with filter This ensures that after switching off the pump the hose and the pump do not run dry This part of the hose keeps th...

Страница 9: ...Suction line not immersed deep enough in the medium Fill the pump with water Check the recommended and used parts and components of the pump e g the connection of the suction hose the connection of th...

Страница 10: ...tion line Clean the suction valve and the strainer Check suction height and discharge head Open the pressure side cutoff taps nozzles etc Have the seal replaced by an authorized specialist Repair or r...

Страница 11: ...nto the intake pipe Contact customer service Check and make sure that a the suction line and all connections are tight b the inlet of the intake pipe including check valve is immersed in the pumped li...

Страница 12: ...ng so open a load in the pressure line e g water faucet to prevent the system from being pressurized Check and make sure that a the suction line and all connections are tight b the inlet of the suctio...

Страница 13: ...asket if necessary Install check valve 8 3 Eliminate blockages If you pump contaminated fluids without an aspiration filter pre filter despite explicit reference not to do so the device may become clo...

Страница 14: ...e pump with clean water Briefly open the screwcap of the metal hose on the boiler and allow the remaining water to drain off Remove suction and discharge lines from the unit For recommissioning the pu...

Страница 15: ...e symbol of the crossed out dustbin on a Waste electrical or electronic equipment indicates that it must not be disposed of with household waste at the end of its life Collection points for waste elec...

Страница 16: ...of conformity will lose its validity Directives This device complies with the following EU EC directives 2014 30 EU EMC Directive 2014 35 EU Low Voltage Directive 2011 65 EU RoHS Directive 2014 68 EU...

Отзывы: