background image

Original User Manual 

 A

REBO

S Upright Vacuum Cleaner Eco 

 

10 

 
 

6. Assembly of the filter unit 

6.1 The HEPA filter has 3 guide lugs. Set the largest guide lug 
into the largest recess of the coarse filter. 
Tighten the HEPA filter by turning it clockwise. It must audibly 
engage. 
6.2 Set the filter unit into the dust container. The rounded guide 
lug must sit exactly in the rounded recess. 
6.3 Reattach the cover to the dust container. Set the arrow on 
the cover just over the arrow at the side of the symbol. 
6.4 Tighten the cover in the direction. It must audibly engage. 
6.5 Reattach the dust container to the motor housing. Set the 
dust container first at the bottom part to the motor housing, so that the electric contacts are 
matched. Then engage it to the top. For this, press the smooth area of the button (1). 

Outlet Filter 

The appliance is also equipped with an outlet filter. It is on the right side of the appliance. 

CAUTION: You cannot remove this filter.   

Cleaning 

 

WARNING: Always disconnect the appliance from the power supply unit before cleaning! 

 

Under no circumstances should you immerse the motor housing in water in order to clean 

it. Otherwise this might result in an electric shock or fire. 

 

Do not use a wire brush or any abrasive items. 

 

Do not use any acidic or abrasive detergents. 

 

The single components are not dishwasher-safe.

 

 

Wipe the casing with a damp cloth. 

 

You can wipe the mains adapter unit with a dry cloth. 

Floor Nozzle 

1. Disconnect the floor nozzle from the suction pipe. 
2. Turn the floor nozzle around, so that you see the lower 
side. 
Turn the lock of the brush roller on the left side 
counterclockwise with tool to unlock the brush roller. the 
lock of the brush roller on the left side. 
3. Pull out the brush roller. 
4. Remove threads and hair wound to the brush. Use 
scissors, if required. 

5. Assembly

Refer to the adjacent figure. 
5.1 Set the brush roller at position (1). Make sure that the 
triangular recess on the brush roller is positioned correctly. 
5.2 Return the bearing of the brush roller into the housing of the floor nozzle (position 2). 
6. Close the lock of the brush roller. It must audibly engage.  
 
 
 
 

Содержание AR-HE-HSSEB

Страница 1: ...l User Manual AREBOS Upright Vacuum Cleaner Eco 1 Upright Vacuum Cleaner Eco AR HE HSSER S B Please follow all security measures in this user s manual to ensure a secure use Thank you for trusting in...

Страница 2: ...ing instructions The appliance is designed exclusively for private use and for the envisaged purpose This appliance is not fit for commercial use The mains adaptor is only suitable for use in dry room...

Страница 3: ...o the specifications on the rating label If the connection cable of this device has been damaged it must be replaced with a special connection cable available from the manufacturer or its customer ser...

Страница 4: ...ttery Status Indicator 4 Dust Container Release Button 5 Handheld Vacuum Cleaner 6 Dust Container Upper Cover 7 Dust Filter Assembly 8 Dust Container Cup 9 Dust Release Button 10 Dust Release Button 1...

Страница 5: ...le Multifunction Button Use the multifunction button to turn the device on and off Also select a power level with this button Press once Turn on the device low power level Press twice Select high powe...

Страница 6: ...ss the release 14 and pull out the attachment at the same time Connection to the Suction Tube You need the adapter 15 for connection to the suction pipe Insert the adapter with the angular side into t...

Страница 7: ...ssible Fig B 3 Fix the cable in the cable guide Fig C Fastening the Wall Holder WARNING Make sure beforehand whether there are cables in the wall which could be damaged CAUTION Place the wall holder s...

Страница 8: ...Using the Device You can use the appliance as a floor vacuum cleaner or as a handheld and upright vacuum cleaner basic unit 1 Disconnect the appliance from the mains when changing the accessory 2 Tur...

Страница 9: ...completely dry and correctly assembled The Filter Unit The filter unit is composed of HEPA filter Coarse filter Proceed as follows to clean the filter unit 1 Empty the dust container as described abov...

Страница 10: ...ing WARNING Always disconnect the appliance from the power supply unit before cleaning Under no circumstances should you immerse the motor housing in water in order to clean it Otherwise this might re...

Страница 11: ...e power supply unit is connected The rechargeable battery is defect Charge the battery Disconnect the appliance from the power supply unit Contact our service or your dealer Weak suction power The bat...