background image

p11

If validation reading of the µconsole file 

(see page 16)

during 

1s.

if transfer 

correct

if transfer 

incorrect

LOAD

4.9.3  Menu

               

: Teleloading of programming files 

                                  

   

READ

CONS

COPY

µCo

µCo

µCo

µCo

LOAD

WAIT

OK

or

ERR

PROG

OPT

ERR

PROG

Saving of the converter programming into the µconsole  

memory.
Teleloading of the programming file contained in the µconsole 

to the converter.

Programming file incorrect: belongs to another type

of instrument.
The file does not correspond to the same options as 

the instrument currently connected.

ERR

ERR

PROG

OPT

M

Reminder:

 

If no key is pressed during 20 s., or if      is pressed the 

instrument will revert to the measure display.

The file stored in the µconsole can be read by validating choice 

READ  

CONS

 . In this case the organigramme for reading the programming of 

the file is the same as for the programming of the instrument 

(see p5).

5.1 Functions which require pressing only 1 key: 

a / Display of the min. value 

    b/ Display of the max. value

INF

02.00

Measure

display

Alternating infor-

mation display
Min. value

5. FUNCTIONS WHICH CAN BE ACCESSED ON 

THE FRONT FACE 

SUP

08.00

Measure

display

Alternating infor-

mation display
Max. value

c / Deleting of the min. and max. values

CLrM

Measure

display

deleting of the recorded min. 

and max., and revert to the 

measure display

M

The instrument will revert to the measure display.

Reminder:

 

If no key is pressed during 20 s., the 

instrument will revert to the measure display.

Note:

 

An exit from mode programming with saving of the confi-

guration will reset the min. and max. values to 0.

Содержание TPI-SI Pt100

Страница 1: ...ed without prior notice TUDES ET R ALISATIONS LECTRONIQUES INSTRUMENTATIONS AUTOMATISME Route de Brindas Parc d activit d Arbora N 2 69510 Soucieu en Jarrest T l 04 72 31 31 30 Fax 04 72 31 31 31 Tel...

Страница 2: ...p10 4 9 Functions which can be accessed from the main menu p10 4 9 1 Display simulation p10 4 9 2 Simulation of the analog output p10 4 9 3 Teleloading of programming files p11 5 FUNCTIONS WHICH CAN...

Страница 3: ...uipment Associated equipment Group II surface instru ment Category 1 for area 0 gas permanently protection mode ia intrinsic safety maximum protection indice protection ensured in case of 2 defects ta...

Страница 4: ...to 70 C Upper connector Lower connectors 26 5 programming keys 3 CONNECTINGS To allow the inserting of the console and ensure a sufficient thermic dissemination mount the instruments vertically on ho...

Страница 5: ...ing of program ming files see p11 LOAD Exit from a sub menu to access next menu access to the programming exit menu Move through the menus downwards or decrease the value shown Move through the menus...

Страница 6: ...e instrument will automatically revert to measure with the former configuration if no key is pressed during 1min NAME INP M Note Press to go on to the next menu Move through the menus choice Upwards m...

Страница 7: ...I Example For a temperature input we have 4 mA 20 00 mA 10 0 100 0 then the value of the analog output will be 4 mA when the displayed measure is 10 0 and 20 mA for a displayed measure of 100 0 Upward...

Страница 8: ...See also the display features p10 PrDI IDLE NAME LdIG NULL BRGT M Note Press to go on to the next menu Move through the menus choice Upwards move increase Validation vertical move Downwards move decr...

Страница 9: ...sage appears alternating with the measure Coding 1 Programming error 2 Gain error 4 Offset error 8 Input calibration error 16 Output calibration error If the instrument detects for instance an offset...

Страница 10: ...ght In the mode programming the menu LdIG allows suppressing the dis play of the last digit the latter being enforced to 0 if OFF is validated Deleting of the unsignificant zeros Suppresses the displa...

Страница 11: ...the measure display The access code is 0000 on factory exit NEW Note The instrument no longer measures during the simulation The analog output will react according to the displayed value SIMU SIMU Val...

Страница 12: ...n the console can be read by validating choice READ CONS In this case the organigramme for reading the programming of the file is the same as for the programming of the instrument see p5 5 1 Functions...

Страница 13: ...obtain 000 0 and the display full scale by 2 points to obtain 0500 0 M OK From the menu READ the performed scale shiftings can be visualised in the submenu INP OFFS 000 3 offset shifting shifting by 1...

Страница 14: ...red to him after processing Without a written agreement on the repair estimate within 30 days products will not be held Complete warranty terms and details available on request 8 LEXIQUE Acess to the...

Страница 15: ...output full scale dOUT F OUT dOdI F OdI OUt I Return value or not of the output in case of self diagnosis error Return value required No return value Return value OUT I NO YES REPL Return value or not...

Страница 16: ...splayable value overload Upper or lower electrical overstepping of the input Self diagnosis error This console is not compatible with the converter currently connected The manufacturer ARDETEM SFERE R...

Страница 17: ...p16...

Страница 18: ...p17...

Отзывы: