WATER HEATING COIL (MODEL SHW4)
ARDENT ENERGY heating units are designed to heat your do-
mestic hot water during the heating season.
The HF65 can accept one or two coils (1 per side). The coil re-
places all but one of the firebrick on the side located.
Procedure:
NOTE:
Ensure installation complies with local
plumbing codes.
1. Remove both side shrouds by unscrewing 4 or 6
screws at back
2. Remove rear heat shield and hammer out the 2
knockouts on the side desired. (see Fig 5)
3. Loosen cross draft angle nuts on side of unit. (2
each side located on outside of firebox).
4. Remove brick from that side.
5. Punch out 2 knockouts at back of stove. Reach in
through punched out holes with a bar extension
and punch out knockouts in primary heat ex-
changer. Knock outs are out of necessity tight. A
sharp blow with a heavy hammer will be required.
6. Position water coil in stove, replace brick and
tighten cross draft angle nuts on side of heater to
hold coil in place.
7. Install mineral wool gasket and plate on outside
and screw tight.
8.
Replace shrouds and heat shield.
TANK CONNECTION
It is recommended that the ‘2 tank” system be used. The first
tank or “Range Boiler” must remain un-insulated to dissipate any
excess heat generated by the hot water coil.
Connection of piping to Range Boiler must be strictly followed as
shown in the Diagram. The 2 shut—off valves must be no smaller
than 3/4 inch GATE valves. Make certain that the PRV (Watts 3L)
and P&TRV (Watts 100XL) are installed in their respective loca-
tions and not vice versa. Maximum pressure setting is 150 psi.
Do not use less than 3/4 inch diameter standard pipe between
range boiler and heater, orientation of pipe must be slightly uphill
from the coil outlet to the upper connection at the tank, otherwise
vapor lock will occur and water will not circulate. Min. Range
Boiler recommended is 30 Imperial gallon capacity.
FIG. 6
REPLACEMENT PARTS LIST
ITEM QTY DESCRIPTION
PART #
1
1
Closer pawl
6261
2
1
Hug lock nut
1442
3
1
Scandinavian baffle
AP014
4
1
Bypass damper
A237R4
5
2
Fin
AP038
6
2
Outside fin
A407R4
7
28”
Ball chain
6110
7-A
2
Chain pendant
6121
8
1
Flame deflector
A533R1
9
1
Down draft baffle
A532R3
10
2
Cross draft angle
A217R8
11
1
Air inlet assembly
6411
12
1
Primary air heat exchange assembly A900R0
13
14
Firebrick 1 1/4 x 4 1/2 x 9
7101
14
1
Door sill
A259R2
15
2
Door hinge
6260
16
60”
Door gasket 5/8 dia. glass rope
7006
17
1
Door liner
A302R1
18
1
Door assembly
A317R3
19
1
Door handle 3/8 ID
6010
20
1
Door closer assembly
6201-1
21
1
Door closer catch
A280R1
22
2
Control handle 5/16 ID
6005
23
1
Bypass bar
A264R10
24
1
Draft control rod assembly
A168R15
25
1
Bypass lever
A239R10