DRAFT CONTROL 

 
Check that it opens and closes freely. 

 

FIREBRICK 

 
Care should be taken when refueling to avoid 
breakage of brick. If frozen wood is burned, do 
not let frozen surface touch brick. Broken brick 
must be replaced to prevent overheating of fire-
box. 
 
Periodically check  the door seal for condition 
and tightness of door fit. If seal shows signs of a 
deteriorating condition, improper fit or signs of leakage, it should 
be replaced. 
 

PAINT 

 
The high temperature paint is designed to withstand tempera-
tures to 650

0

C (1200

0

F). However, should paint discoloration 

happen, the affected areas can be retouched. For the correct 
type of paint contact your dealer. When first using the unit, the 
paint may smoke for 1/2 hour to 1 hour. This is normal and is part 
of the curing process. 
 

HOT WATER SYSTEM 
 

DRAINING AND CLEANING 
 
Cleaning should not normally be necessary unless water tends to 
cause deposits. Should heating efficiency drop off noticeably, the 
coil in the heater should be inspected and if necessary, cleaned. 
 
WHEN YOU HAVE NO WATER 
 
Your heater should not be fired with a dry water coil. If you have 
no water for circulation, the coil should be isolated from the sys-
tem and removed, replacing open holes with two 25 mm (1”) di-
ameter standard washers per hole, using a 19 mm x 25 mm (3/4” 
X 1”) bolt to hold washers together. 

INSTALLATION 
 

LOCATION AND CLEARANCES 

 
Locate unit as central as possible within the home or space to be 
heated. Do not locate near an exit. Do not connect space heater 
to any air distribution duct. 
 
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS: 
 

With single wall pipe connector (see Fig 3) 

With insulated  chimney connected to unit (see Fig 3) 

 

From Heater 

From Connector 

Sidewall 

(A) 460 mm (18”) 

(D) 675 mm (26 1/2”) 

Backwall 

(B) 360 mm (14”) 

(E) 470 mm (18 1/2”) 

Corner 

(C) 460 mm (18”) 

(F) 725 mm (28 1/2”) 

 

From Heater 

From Connector 

Sidewall 

(A) 460 mm (18”) 

(D) 650 mm (25 1/2”) 

Backwall 

(B) 200 mm (8”) 

(E) 290 mm (11 1/2”) 

Corner 

(C) 460 mm (18”) 

(F) 700 mm (27 1/2”) 

INSTALLATION PROCEDURE 

 
1.       Locate heater and floor protection as central as possible 

within the home or space to be heated, observing minimum 
clearances to combustible materials listed below. 

2.       To ensure vertical alignment, suspend a plumb bob from 

the ceiling over the exact center of the flue of the stove, 
and mark a spot on the ceiling to indicate the center of the 
chimney. 

3.       Check that the intended location will not interfere with ceil-

ing joists or rafters before proceeding further. 

4.       Install chimney according to chimney manufacturer’s in-

structions. Read section on Chimney and see Diagram 2. 
Chimney must be a 7” diameter listed chimney suitable for 
wood burning appliances. If an existing masonry chimney 
is to be used read section under Chimney for specific cau-
tions. 

5.       Use plumb bob to ensure that the heater flue is centered 

under the chimney. 

6.       Install chimney connector. The connector must be at least 

24 gauge steel. Insert crimped end of the 7” diameter con-
nector into the heater flue. Install additional connector to 
meet chimney. 

7.       Connect chimney connector to chimney as per chimney 

manufacturer’s instructions. 

 
Combustible floor must be protected by non-combustible material 
extending beneath the heater and to the front and sides as indi-
cated: G—460 mm (18”) ; H—l50 mm (6”) ; 1—150 mm (6”)  
The space beneath the heater must not be obstructed. 
 
Smoke detector must be located a minimum of 4 meters (15’) 
away from heating unit to avoid accidentally setting off smoke 
detector. 
 

NOTE:

 Clearances may be reduced only if combustible material 

is protected (See CSA Installation Code for Solid Fuel 
Burning Appliances and Equipment No B365—M 1991) 

 
Clearances may be reduced by means approved by the regula-
tory authority. 
 

CONNECTION TO CHIMNEY 

 
Chimney suitability is the most important factor that will influence 
the performance of your ARDENT ENERGY heater. If you follow 
these instructions your heater will perform efficiently. If an exist-
ing chimney does not meet the specifications consult your AR-
DENT ENERGY dealer about remedial action. 
Unit must be connected to the chimney using a minimum of el-
bows and horizontal pipe. All horizontal pipe must slope toward 
heater and be installed with seam up. Unit flue opening is de-
signed for the connector to go into the opening. 
 
All connections must be such that any condensation in the flue 
runs back into the unit and not onto the floor. Ensure connection 
pipe is spaced at least 460 mm (18”) from any unprotected com-
bustible material. Do not pass a chimney connector through an 
attic or roof space, closet or similar concealed space, or a floor, 
ceiling, wall or partition of combustible construction. 

FIG. 3 

Содержание HF65R

Страница 1: ...Model HF65R SOLID FUEL SPACE HEATER Box 3637 Smithers BC V0J 2N0 INSTALLATION AND OPERATION INSTRUCTION MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Operation Maintenance Installation...

Страница 2: ...f your heater should be included with your order to assure prompt and accurate service We congratulate you on your choice of the ARDENT ENERGY heating system and may your home fires keep burning Yours...

Страница 3: ...the event of an uncontrolled chimney fire shut the bypass damper and turn down the draft damper com pletely On thermostat models turn down thermo stat If chimney fire does not die down keep a watch o...

Страница 4: ...temperature desired When warming up a cold room there will be an initial temperature overrun then the temperature will stabilize RELOADING 1 Have wood on hand to load firebox 2 Open bypass lever for 3...

Страница 5: ...ng over the exact center of the flue of the stove and mark a spot on the ceiling to indicate the center of the chimney 3 Check that the intended location will not interfere with ceil ing joists or raf...

Страница 6: ...cifications CHIMNEY TERMINATION Chimneys are required to extend at least 915 mm 3 above the highest point where they pass through the roof of the building and at least 610 mm 2 higher than any portion...

Страница 7: ...he hot water coil Connection of piping to Range Boiler must be strictly followed as shown in the Diagram The 2 shut off valves must be no smaller than 3 4 inch GATE valves Make certain that the PRV Wa...

Страница 8: ...OUR MODEL AND SERIAL HERE FOR EASY REFERENCE WHEN ORDERING REPLACEMENT PARTS MODEL ____________________________________________ SERIAL I ___________________________________________ DATE OF INSTALLATIO...

Страница 9: ...e replaced or repaired upon return of the defective part to an au thorized Ardent Energy Ltd dealer 2 Any space heater or part thereof that is replaced or serviced during the three year warranty perio...

Отзывы: