background image

ARC-19516 

ArcVision Technology Corp. 

6

5.  Operation Mode 

 

There are four operational modes on the multiplexer. 
 

Mode 

Description 

Normal 

The multiplexer automatically enters into normal mode, when the power has been put on.   
Press camera selection key to view the full-image. 
Press 

<MULTI-WIN>

 key to view multi-window images. Multi-window supports 4,6,7,8,9,10,13 and 16 

image split. 

This mode supports freeze function under multi-window and full-image. 
Multi-windows freeze: 

1.

 

Under multi-window of the normal mode, presses 

<FREEZE> 

key to enter freeze function. 

User can freeze or release any channel selected, while the LED indicator of the Freeze key is 

ON

2.

 

Press camera channel selection key to select a camera channel that you want to freeze.   
the image of the related camera is than frozen.   
In  order  to  release  frozen  image(s),  press  the  camera  selection  key  again  to  select  a  camera, 
when the LED indicator for the camera channel selection lights up, it indicates that the image 
has been released.   
When the light of the LED indicator for the camera goes off the image is released and begins 
to refresh. 

3.

 

User can freeze and release image(s) for every camera channel independently. 

4.

 

To quit the freeze mode, press 

<FREEZE> 

key again to return to multi-window of normal mode. 

Full-image freeze: 

1.

 

Under full-view of the selected camera channel, press camera channel selection key again to 
freeze the image. The LED indicator of selected channel begins to flash. 

2.

 

Press 

<MULTI-WIN> 

key  or  camera  channel  selection  keys  to  release  the  camera  channel  to 

multi-window image or full-image of the selected camera channel. 

 

This mode supports 2X zoom function under full-image. 

1.

 

Under full-image press 

<ZOOM>

 key, the zoom LED indicator lights up and 2X image displays 

on monitor. 

2.

 

Use the blue arrow key to pan or tilt the 2X image. 

3.

 

Press 

<ZOOM>

 again to leave 2X zoom to normal full-image. 

Auto 
Sequence 

Under normal mode, press 

<SEQ> 

key to enter sequence mode. 

Under this mode, the monitor displays images according to user

s definition of channel sequences and 

dwell time.   
Refer to page 11, 

8.2 CHANNEL SEQUENCE

 for more details. 

To exit sequence mode: 

1.

 

Press camera channel selection key or 

<MULTI-WIN> 

key to exit auto sequence mode and enter 

normal mode. 

2.

 

Press 

<PLAYBACK> 

key to enter playback mode. 

3.

 

Press

 

<MENU> 

key to enter menu set up mode. 

Playback 

In normal or sequence mode, press 

<PLAYBACK> 

key to enter the playback mode. 

Under this mode user can playback VCR that was recorded by this multiplexer. 
It is impossible to view images recorded by another multiplexer. 
Support multi-windows images and full-image view. 
Multi-window format is deferent from normal mode. It only supports 4, 9, and 16 split. 
Support freeze function for multi-win image and full-image. It is the same as normal mode. 
Support 2X zoom function under full-image. It is the same as normal mode. 
Press 

<PLAYBACK> 

key again to exit playback mode and goes back to normal mode. 

Menu set up  Under normal or sequence mode, press 

<MENU> 

key to enter menu set up mode. 

Refer page 9, 

8. Menu set up

 for more details. 

6.  Recording and Playback 

Содержание ARC-19516

Страница 1: ...ARC 19516 Sixteen Channels Duplex Video Multiplexer User s Manual...

Страница 2: ...ion Technology Corp 1 CONTENTS 2003 07 30 V1 1 040064 1 Introduction 2 2 Specification 2 3 Installation 3 4 Function Key Description 5 5 Operation Mode 6 6 Recording and Playback 7 7 Alarm Function 8...

Страница 3: ...property 13 Record event lists power on video loss motion detection and alarm input up to 256 records 14 Supports general and time lapse VCR recording mode for VCR and provides external trigger 2H 12...

Страница 4: ...M 8 External alarm input 8 7 ALARM 9 External alarm input 9 8 ALARM 11 External alarm input 11 9 GND Ground 10 ALARM 14 External alarm input 14 11 ALARM 16 External alarm input 16 12 RELAY OUT N C Rel...

Страница 5: ...UT on the Mutiplexer and the other end to VIDEO IN on another Monitor The video format outputs from this port is programmable and displays full size image of any camera input It acts as a smart video...

Страница 6: ...e press this button again when under normal mode condition 4 5 Press FREEZE key to freeze image s See next page operation mode for detail when under normal or playback multi window image condition 4 6...

Страница 7: ...gins to flash 2 Press MULTI WIN key or camera channel selection keys to release the camera channel to multi window image or full image of the selected camera channel This mode supports 2X zoom functio...

Страница 8: ...516 The acceptable trigger signal is a falling edge negative trigger b RECORD BY SETTING RECORDING TIME The multiplexer can calculate channel switching time by setting recording time at menu set up Th...

Страница 9: ...urs the time in which it is put ON is also recorded It doesn t affect the buzzer and it is able to check whether or not it has once been turned off b When video loss occurs the relay and buzzer will b...

Страница 10: ...bol represents level indication of the menu One symbol indicates that the menu is on level 1 two symbols indicates that the menu is on level 2 and so on c Item indicator Cursor Half tone area indicate...

Страница 11: ...n to the menu on Figure 8 2 Note User must control the date in February by oneself 8 1 4 TIME DISPLAY Set to ON to display time and OFF to turn off the time display 8 1 5 TIME On the menu in Figure 8...

Страница 12: ...t images 1 16 to display the full image of camera 1 16 to skip the sequence to next sequence 8 2 3 SEC dwell time The standby auto sequence time time unit second Press ENTER key to activate the edit p...

Страница 13: ...splay the camera titles and OFF for no title display CAMERA SET UP CAMERA TITLE CAMERA TITLE DISPLAY CAMERA 1 2 3 SET UP CAMERA 4 5 6 SET UP CAMERA 7 8 9 SET UP CAMERA 10 11 12 SET UP CAMERA 13 14 15...

Страница 14: ...rs 168H 240 hours 240H 480 hours 480H 720 hours 720H 960 hours 960H User must set the time to 2H when it is not a time lapse VCR 8 5 2 RECORDING TYPE Recording type can be set to FIELD field by field...

Страница 15: ...4 ALARM OUTPUT Set on YES to turn the relay on if a valid alarm occurs Set on NO to keep relay to the current state 8 6 2 VIDEO LOSS CONFIG On the menu of Figure 8 9 select VIDEO LOSS CONFIG press EN...

Страница 16: ...ct is small the value of sensitivity should increase until a M symbol appear on the right bottom corner of screen 8 6 3 2 4 BUZZER ENABLE Set YES to enable buzzer Once buzzer is enabled the buzzer wil...

Страница 17: ...1 2 c The last field is the time of event occurring d User can use or key to turn the next page or the previous page e Press EXIT to escape the alarm list 8 6 9 CLEAR ALARM LIST On the menu of Figure...

Страница 18: ...CTORY DEFAULT and press ENTER to enter the menu on Figure 8 16 to setting Figure 8 16 8 11 1 LOAD DEFAULT SETTING AND CLEAR ALARM LIST Load the parameters of factory default and erase alarm list 8 11...