background image

ARC-19516 

ArcVision Technology Corp. 

9

8.  Menu Set Up 

 
 

8.0 THE STRUCTURE OF MENU 

 

MAIN MENU                   ▊ 

  ----------------------------- 

▊TIMER/OSD SET UP          
▊AUTO CHANNEL SEQUENCE 
▊CALL CHANNEL SEQUENCE 
▊CAMERA SET UP 
▊VCR SET UP 
▊ALARM PROCESSOR 
▊TERMINAL RES CONFIG 

BEEP WHEN KEY PUSHED:NO 
VIDEO SYSTEM:AUTO 

COLOR BAR 

▊LOAD FACTORY DEFAULT  

Figure 8-1 

 

The main menu is shown in Figure 8-1. Use the main menu as an example, to introduce the structure of menus. 
(a)  The title of menu: 

        Located on the top left side of the first line 

MAIN MENU

(b)  Levels indicator: 

Located on the top right side of the first line. 
The symbol 

  ▊

 represents level indication of the menu. 

One symbol 

  ▊

 indicates that the menu is on level 1, two symbols 

  ▊▊

 indicates that the menu is on level 2

and 

so on. 

 

(c)  Item indicator (Cursor): 
              Half-tone area indicates that the item is available for setting. 
(d)  The type field of the item: 
              Located on the left is the type field of the item. 
              There are three kinds of item indicators: 
                     

  ▊

  :Denotes that there is a sub-menu by pressing <ENTER>, to active it under next menu. 

                     

     

  :Denotes that there is no sub-menu, but user needs to press <ENTER> key to access the items. 

                      No symbol:Denotes that user can press <-> <+> key to set value to the previous or the next and decrease or increase 

the numbers.   

(e)  Item: 

Use the Figure 8-1 for example, 

TIMER/OSD SET UP

 the first item selected by the 

Item indicator

.

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание ARC-19516

Страница 1: ...ARC 19516 Sixteen Channels Duplex Video Multiplexer User s Manual...

Страница 2: ...ion Technology Corp 1 CONTENTS 2003 07 30 V1 1 040064 1 Introduction 2 2 Specification 2 3 Installation 3 4 Function Key Description 5 5 Operation Mode 6 6 Recording and Playback 7 7 Alarm Function 8...

Страница 3: ...property 13 Record event lists power on video loss motion detection and alarm input up to 256 records 14 Supports general and time lapse VCR recording mode for VCR and provides external trigger 2H 12...

Страница 4: ...M 8 External alarm input 8 7 ALARM 9 External alarm input 9 8 ALARM 11 External alarm input 11 9 GND Ground 10 ALARM 14 External alarm input 14 11 ALARM 16 External alarm input 16 12 RELAY OUT N C Rel...

Страница 5: ...UT on the Mutiplexer and the other end to VIDEO IN on another Monitor The video format outputs from this port is programmable and displays full size image of any camera input It acts as a smart video...

Страница 6: ...e press this button again when under normal mode condition 4 5 Press FREEZE key to freeze image s See next page operation mode for detail when under normal or playback multi window image condition 4 6...

Страница 7: ...gins to flash 2 Press MULTI WIN key or camera channel selection keys to release the camera channel to multi window image or full image of the selected camera channel This mode supports 2X zoom functio...

Страница 8: ...516 The acceptable trigger signal is a falling edge negative trigger b RECORD BY SETTING RECORDING TIME The multiplexer can calculate channel switching time by setting recording time at menu set up Th...

Страница 9: ...urs the time in which it is put ON is also recorded It doesn t affect the buzzer and it is able to check whether or not it has once been turned off b When video loss occurs the relay and buzzer will b...

Страница 10: ...bol represents level indication of the menu One symbol indicates that the menu is on level 1 two symbols indicates that the menu is on level 2 and so on c Item indicator Cursor Half tone area indicate...

Страница 11: ...n to the menu on Figure 8 2 Note User must control the date in February by oneself 8 1 4 TIME DISPLAY Set to ON to display time and OFF to turn off the time display 8 1 5 TIME On the menu in Figure 8...

Страница 12: ...t images 1 16 to display the full image of camera 1 16 to skip the sequence to next sequence 8 2 3 SEC dwell time The standby auto sequence time time unit second Press ENTER key to activate the edit p...

Страница 13: ...splay the camera titles and OFF for no title display CAMERA SET UP CAMERA TITLE CAMERA TITLE DISPLAY CAMERA 1 2 3 SET UP CAMERA 4 5 6 SET UP CAMERA 7 8 9 SET UP CAMERA 10 11 12 SET UP CAMERA 13 14 15...

Страница 14: ...rs 168H 240 hours 240H 480 hours 480H 720 hours 720H 960 hours 960H User must set the time to 2H when it is not a time lapse VCR 8 5 2 RECORDING TYPE Recording type can be set to FIELD field by field...

Страница 15: ...4 ALARM OUTPUT Set on YES to turn the relay on if a valid alarm occurs Set on NO to keep relay to the current state 8 6 2 VIDEO LOSS CONFIG On the menu of Figure 8 9 select VIDEO LOSS CONFIG press EN...

Страница 16: ...ct is small the value of sensitivity should increase until a M symbol appear on the right bottom corner of screen 8 6 3 2 4 BUZZER ENABLE Set YES to enable buzzer Once buzzer is enabled the buzzer wil...

Страница 17: ...1 2 c The last field is the time of event occurring d User can use or key to turn the next page or the previous page e Press EXIT to escape the alarm list 8 6 9 CLEAR ALARM LIST On the menu of Figure...

Страница 18: ...CTORY DEFAULT and press ENTER to enter the menu on Figure 8 16 to setting Figure 8 16 8 11 1 LOAD DEFAULT SETTING AND CLEAR ALARM LIST Load the parameters of factory default and erase alarm list 8 11...

Отзывы: