TITAN-SVX Software Manual
page 7
Rev 4.01
2. Communication Overview
2.1. RS-485 & USB Communication Parameters
Communication with TITAN-SVX can be done using an RS-485 multi-drop
network or a direct USB connection. Note that a USB connect will generate a
VCP on the PC.
Following are the communication settings for both direct RS-485 and USB
connection:
Parameter
Setting
Baud Rate
115,200
Byte Size
8 bits
Parity
None
Flow Control
None
Stop Bit
1
Table 2.0
Note that the above settings are fixed and used for all the supported protocols
including MODBUS-ASCII and MODBUS-RTU.
2.2. Ethernet Communication Parameters
Communication with TITAN-SVX can also be done using an Ethernet connection.
Communication between the PC/PLC and TITAN-SVX is done using standard
socket programming.
The default IP address and socket settings can be found below.
IP:
192.168.1.100
Port: 5000
To begin communication with a factory default device, configure the PC control
panel with the following settings.
IP = 192.168.1.nnn
Subnet Mask = 255.255.255.0
Note that the host IP address of the PC should differ from the IP address of the
TITAN-SVX.