The Quick Reference Card provides a quick overview of your spa’s main
functions and the operations accessible with your digital control pad.
Key 1
Press
Key 1
key to turn Pump 1 on at low speed. Press a
second time to turn pump to high speed (with a dual-speed
pump). A third time turns pump off.
A built-in timer automatically turns pump off after
a
prede-
termined period of time, unless pump has been manually
deactivated first.
The “Pump 1” indicator lights up when Pump 1 is on.
With dual-speed pump, indicator will flash when
Pump 1 is on at low speed.
Spa functions
in.k200
series of compact full-function keypads
for in.xe spa systems
Cooldown
While performing this task, the heater is not
allowed to turn on and its icon flashes.
��
Key 2
(2 Pump (or single pump/blower)
(Single-speed pump/blower)
Press
Key 2
key to turn Pump 2 or Blower on. Press a
second time to turn pump or blower off.
(Dual-speed pump)
Press
Key 2
key to turn Pump 2 on at low speed. Press
a second time to turn pump to high speed. A third time
turns pump off.
A built-in timer automatically turns pump off after
a
prede-
termined period of time, unless it has been manually
deactivated first.
The “Pump 2” indicator lights up when Pump 2 is on.
With dual-speed pump, indicator will flash when
Pump 2 is on at low speed.
��
Water temperature regulation
In a regulation cycle, the system first
generates water flow through the heater
housing and the plumbing, in order
to ensure accurate water temperature
readings as well as avoiding heater
activation in dry conditions.
After verifying pump activation and taking a
water temperature reading if required, the
system automatically turns the heater on to
reach and maintain water temperature at
Set Point.
The “Heater” indicator lights up when
the heater is on. It flashes when there
is a request for more heat but the
heater has not yet started.
Smart Winter Mode
Our Smart Winter Mode protects your
system from the cold by turning pumps on
several times a day to prevent water from
freezing in pipes.
The “Smart Winter Mode” indicator
lights up when the Smart Winter
Mode is on.
Troubleshooting
Hr
An internal hardware error has been detected in in.xe.
Contact dealer or service supplier.
HL
The system has shut the heater down because the temperature at the heater
has reached 119°F (48°C). Do not enter the water! Remove the spa cover and
allow the water to cool down, then shut power off and power your spa up
again to reset the system.
Prr
A problem is detected with the temperature probe.
Call your dealer or service supplier.
AOH
Temperature inside the spa skirt is too high, causing the internal temperature
in the in.xe to increase above normal limits. Open skirt and wait until error
clears.
OH
The water temperature in the spa has reached 108°F (42°C). Do not enter the
water! Remove the spa cover and allow the water to cool down to a lower
temperature. Call your dealer or service supplier if problem persists.
FLO
The system does not detect any water flow while the primary pump is
running. Check and open water valves. Check for water level. Clean filter.
If the problem persists, call your dealer or service supplier.
Single pump system
Two pump system