Arctic King WDK Series Скачать руководство пользователя страница 9

Page 9  

Oper

ating

Ins

tructions

Setting the Ti

m

er

• 

When the unit is on, first press 
the Timer button, the Timer OFF 
indicator light illuminates. It indicates 
the Auto stop program is initiated. 
Press it again the Timer ON indicator 
light illuminates.It indicates the Auto 
start is initiated.

• 

When the unit is off, first press the 
Timer button, the Timer ON indicator 
light illuminates. It indicates the Auto 
start program is initiated. Press it 
again the Timer OFF indicator light 
illuminates. It indicates the Auto stop 
is initiated.

• 

Press or hold the  

 and 

 pads to 

change the Auto time by 0.5 hour 
increments, up to 10 hours, then at 
1 hour increments up to 24 hours. 
The control will count down the time 
remaining until start.

• 

The selected time will register 
in 5 seconds and the system will 
automatically revert back to display 
the previous humidity setting.

• 

When the Auto start & Auto stop 
times are set, within the same 
program sequence, indicator lights 
illuminate identifying both ON and 
OFF times are now programmed.

• 

Turning the unit ON or OFF at any 
time or adjusting the timer setting to 
0.0 will cancel the Auto Start/Stop 
function.

• 

When LED display window displays 
the code of P2, the Auto Start/Stop 
function will also be cancelled.

Other Features (cont.)

When Using the Unit

• 

When first using the dehumidifier, 
operate the unit continuously 24 
hours.

• 

This unit is designed to operate with 
a working environment between 
5°C/41°F and 32°C/90°F.

• 

If the unit has been switched off 
and needs to be switched on again 
quickly, allow approximately three 
minutes for the correct operation to 
resume.

• 

Do not connect the dehumidifier to 
a multiple socket outlet, which is 
also being used for other electrical 
appliances.

• 

Select a suitable location, making 
sure you have easy access to an 
electrical outlet.

• 

Plug the unit into a electrical socket-
outlet with earth connection.

• 

Make sure the water bucket is 
positioned correctly so that the unit 
can operate properly.

NOTE

When the water in the bucket reaches 
to a certain level, please be careful to 

m

ove the unit to avoid it spill.

Содержание WDK Series

Страница 1: ...Before using this product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult wi...

Страница 2: ...oduct Safety Precautions 3 Unit Specifications and Features 6 Operating Instructions 7 Installation Instructions 12 Care and Cleaning 13 Troubleshooting Tips 14 Warranty 15 Return Policy 16 CAUTION Ow...

Страница 3: ...ug Do not operate with wet hands or in very humid enviroments It may cause electric shock Do not allow water to come into contact with any electric parts It may cause failure or electric shock Do not...

Страница 4: ...unit and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician Do not place flower vases or other water container on top of the unit Wat...

Страница 5: ...delay fuse or circuit breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not use extension cords or an adapter plugs...

Страница 6: ...itioner you purchased may be slightly different but its operations and fuctions are similar Front 1 Control panel 2 Air intake grille 3 Air outlet grille 4 Air filter behind the grille 5 Water bucket...

Страница 7: ...rol room humidity in a comfortable range 45 55 according to the room temperature The humidity setting function will be invalid NOTE The control panel of the unit you purchased may be slightly differen...

Страница 8: ...when the bucket is ready to be emptied or when the bucket is removed or not replaced in the proper position Auto Shut Off The dehumidifier shuts off after 30 seconds when the bucket is full or when th...

Страница 9: ...ndicator lights illuminate identifying both ON and OFF times are now programmed Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop function Wh...

Страница 10: ...m of the bucket is uneven Otherwise the bucket will fall and cause the water to spill Throw away the water and reposition the bucket The bucket must be in right place and securely seated for the dehum...

Страница 11: ...unit by using two screws placed in the bucket Install the female threaded end of the water hose into the adaptor A See Fig 8 then lead the water hose to the floor drain or a suitable drainage facilit...

Страница 12: ...lation Place the unit in an area where the temperature is between 5 C 41 F and 32 C 90 F and between 30 RH and 80 RH The coils can become covered with frost at at lower temperatures which may reduce p...

Страница 13: ...eria Partially fill the bucket with clean water and mild detergent Swish it around in the bucket empty and rinse 3 Clean the air filter Remove the filter every two weeks based on normal operating cond...

Страница 14: ...niture blocking the front or back of the dehumidifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low bel...

Страница 15: ...NS This warranty does not cover the following 1 Failure caused by damage to the unit while in your possesion other than damage caused by defect or malfunction by its improper installation or by unreas...

Страница 16: ...90 90 Page 16...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: