MAINTENANCE &TROUBLESHOOTING
29
4.5 Operation Environment
●
Height above sea level is below 1000m.
●
Operation temperature range: -10
0
C
~
+40
0
C.
●
Relative humidity is below 90 % (20
0
C), relative humidity is below 50 % (40
0
C).
●
The inclination of the power source does not exceed 10
0
.
●
Protect the machine against heavy rain or in hot circumstance against direct sunshine.
●
The content of dust, acid, corrosive gas in the surrounding air or substance cannot exceed
normal standard.
●
Take care that there is sufficient ventilation during welding. There is at least 30cm free distance
between the machine and wall.
§4.6 Operation Notices
●
Read 1 carefully before attempting to use this equipment.
●
Connect the ground wire with the machine directly and refer to 3.5.
Parameters of piping back sealing welding for mild steel
(
DCEP
)
Piping
diameter
Φ
/mm
Tungsten
electrode
diameter/mm
Gas nozzle
diameter/mm
Welding
wire
diameter/mm
Welding
current/A
Arc
voltage/V
Argon
flow rate
/
L
·
min
-1
Welding
rate
/
cm
·
min
-1
38
2.0
8
2
75
~
90
11
~
13
6
~
8
4
~
5
42
2.0
8
2
75
~
95
11
~
13
6
~
8
4
~
5
60
2.0
8
2
75
~
100
11
~
13
7
~
9
4
~
5
76
2.5
8
~
10
2.5
80
~
105
14
~
16
8
~
10
4
~
5
108
2.5
8
~
10
2.5
90
~
110
14
~
16
9
~
11
5
~
6
133
2.5
8
~
10
2.5
90
~
115
14
~
16
10
~
12
5
~
6
159
2.5
8
~
10
2.5
95
~
120
14
~
16
11
~
13
5
~
6
219
2.5
8
~
10
2.5
100
~
120
14
~
16
12
~
14
5
~
6
273
2.5
8
~
10
2.5
110
~
125
14
~
16
12
~
14
5
~
6
325
2.5
8
~
10
2.5
120
~
140
14
~
16
12
~
14
5
~
6
Notice: the above parameters originate from
《
Welding Dictionary
》
P167, Volume 1 of Edition 2.
Содержание ArcoMiG LCD 250C
Страница 1: ...I ...
Страница 3: ...CONTENT III ...
Страница 34: ...MAINTENANCE TROUBLESHOOTING 34 5 3 Electrical principle drawing ...
Страница 38: ...MAINTENANCE TROUBLESHOOTING 38 ...