you press and loosen the trigger quickly, the air will stop. After this you can press the trigger for a
longer period of time to restart the machine.
Account for the alarm indicator:
1) When the machine over-heats or is over-current, the yellow indicator (lamp 2) on the front panel will
light up.
a)
Over-heat: The alarm will release after the period of fan cooling. You can then restart the
machine.
b) Over-current: The alarm is beyond resetting. You must ask an authorised technician to check the
machine.
2) When any of the torch parts (include Tip, electrode, shield cup and air distributor) aren’t installed
correctly, the red indicator (lamp 3) lights up.
3) When the air pressure is too low, the indicator (lamp 3) will be on continually.
4) If the air distributor is not installed correctly there is nil alarm while operating the machine. When you
press the trigger, there is no arc and no load as well. Please check torch consumables.
11