Grind Mode
6000V:
Press and hold the “ON/Delay” button to turn on the Grind mode. Press briefly to turn off the
Grind mode.
5000V, 7000VX, and iDF-48:
Turn the Sensitivity knob down until the LCD readout indicates “Grind”
(see Figures 2a, 2b and 3).
5500V and 7500VX
: Press the “M” mode button until “Sensitivity” or the Sensitivity icon is flashing,
then press the “-” button until the LCD readout indicates “Grind” (see Figures 2a and 2b).
NOTE:
Other modes will not work when in Grind mode.
Located
on filter
edge or
back
Python 90 x 110mm Shell
Auto-Darkening Filter
03-OP or 04-OP
Inside Cover Plate
06-OP Outside
Cover Plate
Python Filter Holder
Headgear
Python Helmet Assembly
Sweatband
Cover Plate
Guide Clip
Outside Cover Plate
Filter Holder Instructions:
Slide filter and
inside cover plate into filter holder. Slide top
tabs into catches on shell Rotate down and
snap lower locks into lower catches on shell.
Catches
Filter Holder
Top Tabs
Lower Locks
Lower
Catches