FFLB User Manual 200214 Page 3 of 8
1.
TECHNICAL DATA
1.1
GENERAL DATA
a.
Control/Auxiliary voltage
:
230V AC or 115V AC (Based on Model Selected in Table-1)
b.
Control protection
:
Miniature Circuit Breaker (MCB)
c.
Over Temperature Protection
:
Thermal Switch
d.
Degree of protection
:
IP20
e.
Overall Dimensions
:
1.2
LOAD DATA
Model
Aux.
Supply
Test Voltage
Power
Load Steps
FFLB1KW-110V AC
230V AC
110V AC
1KW
0.25KW x 4
FFLB1KW-230V AC
230V AC
230V AC
1KW
0.25KW x 4
FFLB3KW-110V AC
230V AC
110V AC
3KW
1KW x2; 0.5KW x1; 0.25KW x2
FFLB3KW-230V AC
230V AC
230V AC
3KW
1KW x2; 0.5KW x1; 0.25KW x2
FFLB5KW-110V AC
230V AC
110V AC
5KW
2KW x1; 1KW x2;
0.5KW x1; 0.25KW x2
FFLB5KW-230V AC
230V AC
230V AC
5KW
2KW x1; 1KW x2;
0.5KW x1; 0.25KW x2
FFLB1KW-110V AC_A
115V AC
110V AC
1KW
0.25KW x 4
FFLB1KW-230V AC_A
115V AC
230V AC
1KW
0.25KW x 4
FFLB3KW-110V AC_A
115V AC
110V AC
3KW
1KW x2; 0.5KW x1; 0.25KW x2
FFLB3KW-230V AC_A
115V AC
230V AC
3KW
1KW x2; 0.5KW x1; 0.25KW x2
FFLB5KW-110V AC_A
115V AC
110V AC
5KW
2KW x1; 1KW x2;
0.5KW x1; 0.25KW x2
FFLB5KW-230V AC_A
115V AC
230V AC
5KW
2KW x1; 1KW x2;
0.5KW x1; 0.25KW x2
Table 1
Series
W x D x H in mm
FFLB1KW
482 x 375 x 179
FFLB3KW
482 x 375 x 311
FFLB5KW
482 x 375 x 356