6
2.2 Connection to the control signal
For greater stability, it is recommended to use a DMX signal amplifier, if you connect more than 20 units or
the signal cable is greater than 60 m in length.
POWER
junction box
junction box
L (Brown)
N (Blu)
E (Green/Yellow)
L (Brown)
N (Blu)
E (Green/Yellow)
L
L
N
N
E
E
Fig.3
junction box
junction box
Pin3
Pin3
2
2
1
1
4
4
5
5
SIGNAL IN
SIGNAL OUT
Pins:
• Pin 1 Shield
• Pin 2 (black)
• Pin 3 (white)
• Pin 4 (green)
• Pin 5 (red)
Functions:
• Gnd/0
• Data input (-)
• Data input (+)
• Data output (-)
• Data output (+)