This appliance conforms to CMR 248 3.00—10.00  

 

MA Code -  C O Detector 

5.08: 

Modifications to NFPA-54, Chapter 10 

 

 (2) Revise 10.8.3 by adding the following additional requirements: 
 
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, includ-
ing those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of 
the venting, including but not limited to decks and porches, the following requirements shall be satisfied:  
 
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber 
or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be 
installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each 
additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner 
to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors 
 
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm 
and battery back-up may be installed on the next adjacent floor level. 
 
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to 
comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be 
installed. 
 
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 
720 and be ANSI/UL 2034 listed and IAS certified.  
 
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade di-
rectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-
half (1/2) inch in size, 

"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS". 

 
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, 
the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.  
 
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  
 
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and  
 
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole 
or in part for residential purposes.  
 
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally 
vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installa-
tion of the equipment and the venting system shall include: 
 
1. Detailed instructions for the installation of the venting system design or the venting system components; and 
 
2. A complete parts list for the venting system design or venting system.  
 
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall hori-
zontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be 
satisfied by the manufacturer: 
 
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  
 
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instruc-
tions. 
  
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting 
instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.  

For the State of Massachusetts, installation and repair must be done by a plumber 
or gasfitter licensed in the Commonwealth of Massachusetts. 
 
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in 
length. 
 
The State of Massachusetts requires the installation of a carbon monoxide alarm in 
accordance with NFPA 720 and a CO alarm with battery back up in the same room 
where the gas appliance is installed. 
 
For the State of Massachusetts the appliances individual shut – off must be a t-
handle type valve. 

Содержание 3600-dvtr24n

Страница 1: ...rtified kit is used Conversion kit required for Propane use WARNING If the information in this manual is not followed exactly fire or explosion may result causing property damage personal injury or lo...

Страница 2: ...R OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector ob...

Страница 3: ...ency therefore less expensive to operate Adjustable Flame The flame aesthetics and heat output can be adjusted to suit the owner s moods and heating needs Solid Construction It is constructed mainly o...

Страница 4: ...0 Approved Vent Components 21 Venting Components Parts List 22 Venting Rear Vent 24 Venting Top Vent 25 Horizontal Venting Instructions 26 Vertical Venting Instructions 27 Operation Instructions Safet...

Страница 5: ...and circulating air passageways for the appliance be kept clean Venting terminals shall not be recessed into a wall or siding This gas appliance must not be connected to a chimney flue serving a sepa...

Страница 6: ...ance must be installed by a qualified gas appliance installer The installation must conform with the local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 NF...

Страница 7: ...Optima ag3600 7 APPLIANCE DIMENSIONS...

Страница 8: ...ewall clearance C 6 305 mm from edge of unit Unexposed Back Sidewalls 0 Internal Ceiling 40 1016 mm from floor Floor 0 Mantle See Chart Vertical Vent 1 25 mm to outside surface Horizontal Vent 1 25 mm...

Страница 9: ...r in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical code CSA C22 1 Remove or open the bottom louver grill Remove the junction box cover Run the li...

Страница 10: ...eplacing the Glass Door Check the condition of the glass and the gasket before installing door Carefully hook the door onto the 4 tabs on the top of the firebox 2 left 2 right Connect the door latches...

Страница 11: ...ent connections must be made before installing the logs and embers on the pan burner NOTE Improper placement of logs may cause sooting on the internal parts and glass and will not be covered under war...

Страница 12: ...Optima ag3600 12 STEP 1 PLACE REAR LOG 146 ON PINS AND BURNER AS SHOWN LOG PLACEMENT CONTINUED STEP 2 PLACE LEFT LOG 144 ON PIN AND LOG AS SHOWN 144 146...

Страница 13: ...Optima ag3600 13 STEP 3 PLACE FRONT LOG 147 ON PINS AND BURNER AS SHOWN STEP 4 PLACE RIGHT LOG 145 ON PIN AND LOGS AS SHOWN LOG PLACEMENT CONTINUED 147 145...

Страница 14: ...Optima ag3600 14 STEP 5 PLACE RIGHT LOG 148 AND EMBERS AS SHOWN LOG PLACEMENT CONTINUED 147 146 144 145 148 STEP 6 PLATINUM EMBERS SHOULD BE PLACED ON BURNER AS SHOWN...

Страница 15: ...for venting See the ALLOWABLE TERMINATION LOCATIONS page 20 in this manual When the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring the a...

Страница 16: ...al shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such damage is...

Страница 17: ...RENCH HERE The pilot flame should have the characteristic as shown in the illustration to the right The flame should not have yellow tips but should engulf the thermocouple and thermopile It can be ad...

Страница 18: ...tend warranty to them OPTIONAL WALL SWITCH OR THERMOSTAT Thermostat wall switch wire table Recommended Maximum Lead Length for two wires Wire Size Max Length 14 GA 50 Ft 15 24 M 16 GA 32 Ft 9 75 M 18...

Страница 19: ...er 1 2 Remove the top vent heat shield cover 2 3 Remove the outer collar assembly 3 4 Remove the exhaust collar assembly 4 5 Rotate the exhaust collar assembly and the outer collar assembly to the rea...

Страница 20: ...veranda porch deck or balcony 12 inches 30 cm E Clearance to unventilated soffit 21 inches from center of termination 53 cm 21 inches from center of termination 53 cm F Clearance to outside corner 0...

Страница 21: ...local code restrictions if any regarding the installation of this type of gas appliance Observe the venting charts given in this manual Use vent spacers between the inside 4 101mm and outside 7 178mm...

Страница 22: ...B Flashing 7 12 12 12 943S 48 Pipe Length Galvanized 902 Storm Collar 953 11 14 Adjustable Pipe Length Black 911B Vinyl Siding Standoff 950 17 24 Adjustable Pipe Length Black 917B Wall Strap 988 45 El...

Страница 23: ...2B DIRECT TEMP 12 ADJ PIPE LENGTH BLACK 1604084 4DT AJ14 DIRECT TEMP TELESCOPE ADJ LENGTH 1604084B 4DT AJ14B DIRECT TEMP TELESCOPE ADJ LEN BLACK 4 x 6 5 8 FITTINGS 1604215 4DT EL45 45 DEGREE ELBOW 160...

Страница 24: ...an Archgard SVK 1 TK 1 or 24 snorkel cap part SNK 24 For best venting performance here are some general venting rules 1 Use only vent systems and components certified for use with this appliance 2 Mai...

Страница 25: ...2m maximum The total horizontal run up to 20 6 1m maximum Note 4 1 2m minimum of vertical height required Note Maximum vent lengths may be subject to local codes For best venting performance here are...

Страница 26: ...H Value Total length of all horizontal sections in feet Note For H V values for 45 venting see Chart IV Elbows are not counted in H or V values Vent chart starts from the top of the unit No restrictor...

Страница 27: ...t of the appliance The rear vent configurations do not require a vent restrictor Example 1 V Value 3A 12 1C 3 15 H Value 2B 4 4 V Value Total length of all vertical sections in feet H Value Total leng...

Страница 28: ...all a qualified service technician Force or attempted repair may result in a fire or explosion BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because so...

Страница 29: ...s established hold knob depressed in the PILOT position for approximately 60 sec 2 Release knob If pilot should go out turn the control knob to OFF position and repeat steps 1 2 and 3 Note this will a...

Страница 30: ...ake care not to break them After cleaning the logs must be replaced as per the instructions in this manual Once a year have a qualified service technician Completely inspect the appliance and the vent...

Страница 31: ...may be defective Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pilot immed...

Страница 32: ...e is yellow and lazy check for lint etc around primary air shutter Increase primary air by opening the primary air shutter if necessary 2 Check for proper placement of the logs and branches Ensure log...

Страница 33: ...ghten screw Remove the glass door embers coals and firebox liner panels Remove the 4 screws holding the burner tray and remove it Remove the 2 screws holding the burner and lift it out Use a wrench to...

Страница 34: ...icity to the appliance Shut off the gas supply to the appliance and disconnect the gas line to the appliance Remove the glass door logs coals and burner Disconnect the two wires at the front of the va...

Страница 35: ...E SIT 820 Nova DATE PURCHASED NAME ADDRESS CITY STATE PROV COUNTRY ZIP POST CODE PHONE NUMBER OWNER COMPANY NAME ADDRESS PHONE NUMBER RETAILER COMPANY NAME ADDRESS PHONE NUMBER INSTALLER MODIFICATIONS...

Страница 36: ...0144 LOG LEFT HAND 1 EA 310 0145 LOG RIGHT HAND 1 EA 310 0146 LOG REAR 1 EA 310 0147 LOG FRONT LEFT TWIG 1 EA 310 0148 LOG FRONT RIGHT TWIG 1 EA 311 0077 BRICK PANEL RIGHT HAND 1 EA 311 0078 BRICK PA...

Страница 37: ...Optima ag3600 37 C A B BURNER ORIFICE BURNER PAN L K J REPLACEMENT PARTS FAN F G H I E D M...

Страница 38: ...ur Authorized Archgard Dealer WHAT TO DO IN THE EVENT OF A PROBLEM Thoroughly read your manual If you cannot solve the problem contact your Archgard Dealer or representative When calling for help plea...

Страница 39: ......

Страница 40: ...me Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LIN...

Страница 41: ......

Страница 42: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Telephone 604 820 8262 Fax 604 820 8881 Telephone Toll Free 1 877 820 9800 Fax Toll Free 1 866 820 2802 Website www archgard com...

Отзывы: