31-DVIM33
32
CONVERSION KIT INSTRUCTIONS
IMPORTANT:
This fireplace is Natural gas ready. If converting to LP gas, follow instructions below
WARNING:
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these
instructions is not followed exactly, a fire, explosion or productions of carbon monoxide may result, causing property dam-
age, personal injury or loss of life. The qualified service agency is responsible for proper installation of this kit. The in-
stallation is not proper and complete until operation of the converted appliance is checked as specified in the instructions
supplied with the kit. Refer to appliance owner’s manual or product data plate for proper inlet and manifold pressure
adjustments and orifice sizing.
IMPORTANT:
For high altitude installations above 4500 ft (1372 meters), consult local gas distributor or the authority
having jurisdiction for proper de-rating methods.
KIT NUMBERS: 31-CKMLP for LP gas and 31-CKMNG for Natural Gas
KIT INCLUDES:
1- Gas conversion label
1- Burner orifice (#50 for LPG) (#33 for Natural Gas)
1- Gas type label
1- SIT 820 valve conversion kit
PREPARE THE FIREPLACE
Remove the surround, glass frame assembly, logs and brick (if applicable).
Remove the burner cover by removing the two screws at the back and lifting straight up.
Remove burner by removing the screw on each side of the burner and sliding the burner to the right and then tilt up.
WARNING:
SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE
SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ELECTRICAL POWER
Shut off gas supply to the appliance.
Install NEW LP Burner orifice as per instructions.
Remove the burner orifice using a 1/2” wrench. Replace with the
orifice supplied with the conversion kit. Use a small amount of
pipe sealant.
MAKE SURE APPLIANCE IS COOL
PILOT CONVERSION
Using a 7/16” wrench and loosen the pilot
hood 1/4 turn. Slide the tab at the bottom of
the orifice hood all the way so the red side
(propane) with the hole in it is showing.
Tighten the pilot hood back up so that it is
lined up with the two probes on both sides of
the pilot assembly.
LP has hole
and red dot
Natural Gas
Wrench here
Содержание 31-DVIM33
Страница 39: ...31 DVIM33 39 NOTES ...
Страница 42: ......
Страница 43: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com ...