Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
57
7.2 Flame Parameters
The oxygen fuel parameters, in Fig 7.2, control time delay in IO operation, and whether use
high adjustment.
F1 Common
F2 Flame
F3 Plasma
F5 System
F6 Import F7 Export
F8 Save
Ignition time
0.00
s
Low preheat time
10.00
s
High preheat time
0.00
s
Pierce 1 time
0.00
s
Pierce 2 time
0.00
s
Pierce 3 time
0.10
s
Blow time
0.00
s
Torch up time
0.00
s
Torch down time
0.00
s
Pierce up time
0.00
s
Pierce down time
0.00
s
THC enable
No
<->
Hold preheat
Yes
<->
Edge cutting enable
No
<->
F4 Power
Fig 7.2 Flame Parameters
Ignition Time: the time delay of opening ignition I/O.
Low Preheat Time: The preheating time before perforating the steel plate. Enter any
positive number ,unit is s. During the low pressure preheating process, you can
prolong the preheating time by pressing “stop” key, then the preheating time will
delay until you press the “start” key to start to high pressure preheat delay.
High Preheat Time: Like Low Preheat Time except open different IO.
Pierce 1 time: Perforation time with low pressure fuel gas. Enter any positive
number ,unit is s.
Pierce 2 time: Perforation time with middle pressure fuel gas. Enter any positive