8.4. Heating system configuration menu
This menu permits the selection of the heating system type which the boiler is connected to.
The various temperature sensors connected to the electronic control board can be set active or not.
Different types of heating systems which can be selected:
Heating system
configuration[P37]
Description
Different types of water
temperature sensors used
Different types of
circulation pumps
0000
Basic heating
Heating system delivery
temperature sensor
Heating system return
temperature sensor
Heating system circulation
pump (PI)
Bypass pump (PR)
0001
Heating
+ hot sanitary water
storing tank
Heating system delivery
temperature sensor
Heating system return
temperature sensor
Hot sanitary water storing tank
temperature sensor - top
Heating system circulation
pump (PI)
Bypass pump (PR)
Hot sanitary water storing
tank circulation pump (PB)
0002
H "Puffer" tank
Heating system delivery
temperature sensor
Heating system return
temperature sensor
"Puffer" tank top side temperature
sensor
"Puffer" tank bottom side
temperature sensor
Heating system circulation
pump (PI)
Bypass pump (PR)
"Puffer" tank circulation
pump (PB)
0003
Heating
+ hot sanitary water
storing tank
+ solar panels
Heating system delivery
temperature sensor
Heating system return
temperature sensor
Hot sanitary water storing tank
temperature sensor - top
Hot sanitary water storing tank
temperature sensor - bottom
Solar panels temperature sensor
Heating system circulation
pump (PI)
Bypass pump (PR)
Hot sanitary water storing
tank circulation pump (PB)
Solar panels circulation
pump (PS)
0004
Heating
+ "Puffer" tank
+ solar panels
Heating system delivery
temperature sensor
Heating system return
temperature sensor
"Puffer" tank top side temperature
sensor
"Puffer" tank bottom side
temperature sensor
Solar panels temperature sensor
Heating system circulation
pump (PI)
Bypass pump (PR)
"Puffer" tank circulation
pump (PB)
Solar panels circulation
pump (PS)
PROCEDURE
INSTRUCTIONS
BUTTONS