ARC Flex Mini Скачать руководство пользователя страница 15

 

 

Flex Mini Instruction Manual 

November 2015 

Page 14 of 17 

 

PB3

PB4

PB5

P B6

P B8

PB7

START

Type 3

STOP

PB3

PB4

PB5

P B6

P B8

PB7

P B2

ON

OF F

Type 2

PB3

PB4

PB5

P B6

P B8

PB7

P B2

Type 1

PB1

4. OPERATING PROCEDURE 

 

General Operating Procedure 

 
 
Keypad Type 1: 

 

The transmitter is powered on and operated by pressing any button on the 
keypad (green blinks on Status LED).  The transmitter goes into sleep mode 
after 5 minutes of inactivity (buttons not pressed).  Press any button to wake 
up the transmitter and continue operation. 

 

 
 
Keypad Type 2: 

 

The transmitter is powered on by pressing the On/Off button one time for up 
to 2 seconds (green on Status LED); the receiver main is also activated at 
the same time.  The Status LED will blink green every 4 seconds thereafter 
for up to 5 minutes when no buttons are pressed (transmitter standby).  After 
5 minutes the transmitter will go into sleep mode.  Press the On/Off button for 
up to 1 second to wake up the transmitter and continue operation.  Shut off 
the transmitter power by pressing the On/Off button for up to 2 seconds (red 
on Status LED and then off); the receiver main is also deactivated at the 
same time.  The system will not work when pressing any buttons prior to 
initiating the On/Off command (Status LED blinks 2 red).   

 
 

Keypad Type 3:

 

 

 

The transmitter is powered on by pressing the Start button one time for up to 
2 seconds (green on Status LED); the receiver main is also activated at the 
same time.  The same Start button becomes an auxiliary function thereafter.  
The Status LED will blink green every 4 seconds thereafter for up to 5 
minutes when no buttons are pressed (transmitter standby).  After 5 minutes 
the transmitter will go into sleep mode.  Press the Start button again for up to 
1 second to wake up the transmitter and continue operation.  Shut off the 
transmitter power by pressing the Stop button for up to 2 seconds (red on 
Status LED and then off); the receiver main is also deactivated at the same 
time.  The system will not work when pressing any buttons prior to initiating 
the Start command (Status LED blinks 2 red).   
 
 

Changing Transmitter Batteries

 

 
Changing transmitter batteries (“AA” alkaline battery x 2) by unscrewing the battery cover 
located on the backside of the transmitter counterclockwise.  During battery installation 
make sure the batteries are installed correctly, “+” to “+” charge and “–” to “–” charge.  Also 
make sure the screw is tightened after battery installation to avoid water, moisture, dirt, 
grease, or other liquid penetration.    

   
 
   

 

 

 

 

       

 
   

 

 

 

        

 

 

Содержание Flex Mini

Страница 1: ...FLEXMini Instruction Manual...

Страница 2: ...Hsin Ya Road Chien Chen District Kaohsiung Taiwan Telephone 886 7 812 8112 Fax Number 886 7 812 8119 Website www advanced radiotech com E mails info advanced radiotech com sales advanced radiotech com...

Страница 3: ...rnal Illustration 6 2 Function Settings 2 1 Transmitter 2 1 1 Channel Settings 7 2 1 2 Keypad Type Settings 8 2 1 3 Transmitter Inactivity Sleep Timer Settings 8 2 1 4 Remote Pairing 9 2 2 Receiver 2...

Страница 4: ...ge 3 of 17 2 4 6 8 9 1 3 5 7 1 GENERAL SYSTEM INFORMATION 1 1 TRANSMITTER 1 1 1 External Illustration 1 Button 1 PB1 6 Button 6 PB6 2 Button 2 PB2 7 Button 7 PB7 3 Button 3 PB3 8 Button 8 PB8 4 Button...

Страница 5: ...5 7 10 12 11 13 1 1 2 Internal Illustration 1 Button 1 PB1 8 Button 8 PB8 2 Button 2 PB2 9 Status LED Indicator 3 Button 3 PB3 10 RF Encoder Board 4 Button 4 PB4 11 Function Dipswitch 5 Button 5 PB5...

Страница 6: ...November 2015 Page 5 of 17 4 1 5 6 2 3 7 1 2 RECEIVER 1 2 1 External Illustration 1 COM LED Indicator 5 System Information 2 Status LED Indicator 6 Cord Grip 3 Power LED Indicator 7 Mounting Bracket 4...

Страница 7: ...Flex Mini Instruction Manual November 2015 Page 6 of 17 1 2 2 Internal Illustration 1 RF Decoder Board 2 AC Line Filter Relay Board 3 Power Transformer...

Страница 8: ...ss is completed Make sure the receiver power is turned on during the process Skip this process if changing receiver channel is not required Exit transmitter Function Setting Mode by taking out the bat...

Страница 9: ...by taking out the batteries and move the function dipswitch back to off position Note when selecting a new keypad type make sure each button press does not exceed 3 seconds 2 1 3 Transmitter Inactivit...

Страница 10: ...r Pairing Output data receiver Receiving data transmitter Press and hold the Pairing button Press and hold PB4 JP1 Open Method After entering the Remote Pairing Mode output receiver data by press and...

Страница 11: ...r is turned off keypad type 2 or Stop button is pressed keypad type 3 Dipswitch 1 on the right Normal and Toggled Interlocked Settings Position Dip 1 2 Dip 3 4 Dip 5 6 Dip 7 8 Set to 00 PB1 2 Normal N...

Страница 12: ...the Stop button is pressed keypad type 3 JP4 JP8 Reserved for future functions 2 2 3 External Programming Other settings not listed in this manual can be programmed via the external programmer unit Pl...

Страница 13: ...2 of 17 WALL 0 68 2 72 4 17 17 6 69 8 14 69 106 mm 170 207 3 RECEVIER INSTALLATION For keypad type 2 and type 3 setups For 9 36VDC power supply wire 1 corresponds to the negative charge wire 3 corresp...

Страница 14: ...ong the guided track to secure the receiver to the mounting bracket see below Make sure the screws are tightened after installation Remove the receiver by pressing down the bracket release and pull th...

Страница 15: ...me The system will not work when pressing any buttons prior to initiating the On Off command Status LED blinks 2 red Keypad Type 3 The transmitter is powered on by pressing the Start button one time f...

Страница 16: ...sed For example when 2 red blinks are shown on the Status LED press all buttons one at a time to see which one is jammed or defective A good working button will not display any lights on the Status LE...

Страница 17: ...ensitivity 104dBm Antenna Impedance 50ohms Responding Time 50mS Transmitting Power 1mW Enclosure Type NEMA4 Enclosure Rating IP66 Output Contact Rating 250V 8 Amps Transmitter Operating Voltage 3 0VDC...

Страница 18: ...g the CE Mark Directive 2006 42 EC and Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directives 2004 108 EC R TTE Directive 1999 5 EC are fulfilled as laid out in the guideline set do...

Отзывы: