Flex ECO 4S/4X/8S/8X/12S/12X Instruction Manual
April 2015
Page 24 of 36
4.2.4 Jumper Settings
Jumper settings are applied to functions such as the Start
function, transmitter standard right/left or inline pushbutton
configurations, firmware version, system testing and remote
pairing function.
Jumper Settings
Function
JP3
(Opened)
Standard A/B selector sequence
- Output
relay A activated at A position, output relay B activated at B position,
both relays activated at A+B position.
JP3
(Inserted)
Reversed logic A/B selector sequence
- Output
relay B activated at A position, output relay A activated at B position,
both relays deactivated at A+B position.
JP4
(Opened)
JP5
(Opened)
Standard right/left pushbutton configuration.
JP4
(Inserted)
JP5
(Opened)
Inline top/bottom pushbutton configuration for PB1 to PB8.
JP4
(Opened)
JP5
(Inserted)
Inline top/bottom pushbutton configuration for PB1 to PB12.
JP4
(Inserted)
JP5
(Inserted)
Inline top/bottom pushbutton configuration for PB1 to PB4.
JP6
(Inserted)
System firmware version.
JP7
(Inserted)
For system testing only, receiver MAIN relays disabled.
JP8
(Blank)
Receiver-to-transmitter remote pairing.
(requiring pressing the PAIRING button on receiver)
JP8
(Inserted)
Receiver-to-transmitter remote pairing.
(do not require pressing the PAIRING button on receiver)
Содержание ECO Series