16
1. Welding cable quick socket (-)
On MMA mode, used for connecting the work piece.
On TIG mode, used for connecting the torch.
On MMA mode,When welding with 6010 electrode,used for connecting the electrode holder.
2.Welding cable quick socket (+)
On TIG mode, used for connecting the work piece.
On MMA mode , used for connecting the electrode holder.
On MMA mode,When welding with 6010 electrode,used for connecting the work piece.
3.Fan
Cool down the hot components inside welding machine
4.Power cord
The mixed-colored wire must be firmly grounded; the rest wires connect to 1- phase AC
220/230V ~50/60Hz power supply.
5.Main switch
Switch for 220/230V single-phase AC power.Turn on this switch (on the position:
“
ON
”
), then
the Power on indicator lights up, and the fan runs.
4-5 Installation
Warning!
An electric shock can be fatal. If the machine is plugged into the mains
electricity supply during installation, there is high risk of very serious injury and
damage. Do not use the functions described here until you have read and
completely understood “safety rules” in the beginning.Only carry out work on the
machine when
- the mains switch is on turn-off position,
- the machine is unplugged from the mains.
● Installation environment requirements
1. It should be placed indoors without direct sunlight, rainproof, low humidity and less dust.
The ambient air temperature range is -10
℃
~+40
℃
.
2. The inclination to the ground should not exceed 10°.
3. There should be no wind in the welding station, if any, it should be covered.
4. The welding machine is more than 20cm away from the wall, and the distance between the
welding machine is more than 10cm.
5. When using water-cooled welding torch, pay attention to anti-freezing.
●
Power supply and cable requirement
Please note the size of fuse and circuit breaker in the table below are for reference only.